Wiring
7.7

Encoder

7.7.1

Supply voltage

Connector X40a
Supply voltage
1
2
Operating Manual PMCprimo C2
1004683-EN-02
WARNING!
Electric shock!
Safe electrical isolation must be ensured for the external power supply that
generates the supply voltage. Failure to do so could result in electric shock.
The power supplies must comply with EN 62368-1, EN 61558-2-6, 08:2009.
Pin
2
X40a
4
Supply voltage for encoder at X41
X40a
2
V+
V+
4
Designation
Encoder Supply
0 V Encoder Supply
*
Description
Supply voltage for ex-
ternal encoder
Supply voltage for ex-
ternal encoder (0 V)
X40a/2 is linked internally
to X41/4 and X40a/1 to
X41/2
*If the link is removed, earth
N
fault monitoring must be
used in accordance with
EN 60204 / VDE 0113.