PNOZ mmc2p
Configurable compact control systems PNOZmulti Mini
}
Operating Manual 1002103-EN-02

Advertisement

Table of Contents
loading

Summary of Contents for Pilz PNOZ mmc2p

  • Page 1 PNOZ mmc2p Configurable compact control systems PNOZmulti Mini Operating Manual 1002103-EN-02...
  • Page 2 Preface This document is a translation of the original document. All rights to this documentation are reserved by Pilz GmbH & Co. KG. Copies may be made for internal purposes. Suggestions and comments for improving this documentation will be gratefully received.
  • Page 3: Table Of Contents

    Connect the base unit and expansion modules Section 6 Commissioning General wiring guidelines Interface configuration Preparing for operation Download modified project to the PNOZmulti system Section 7 Operation LED indicators Section 8 Technical details Section 9 Order reference Product Accessories Operating Manual PNOZ mmc2p 1002103-EN-02...
  • Page 4: Operating Manual Pnoz Mmc2P

    Introduction Introduction Validity of documentation This documentation is valid for the product PNOZ mmc2p. It is valid until new documenta- tion is published. This operating manual explains the function and operation, describes the installation and provides guidelines on how to connect the product.
  • Page 5 Introduction INFORMATION This gives advice on applications and provides information on special fea- tures. Operating Manual PNOZ mmc2p 1002103-EN-02...
  • Page 6: Overview

    Scope of supply Expansion module PNOZ mmc2p Jumper Unit features Using the product PNOZ mmc2p: Communication module for connection to a base unit from the configurable control systems PNOZmultiMini. The product has the following features: Can be configured in the PNOZmulti Configurator...
  • Page 7: Front View

    Overview Front view Power Legend: X2: Serial interface RS232 LED: – Power Operating Manual PNOZ mmc2p 1002103-EN-02...
  • Page 8: Safety

    Safety Intended use The expansion module PNOZ mmc2p is used for communication of the configurable safety relay PNOZmulti Mini via a serial interface RS232. The expansion module may only be connected to a base unit PNOZmulti Mini (for details of the base units PNOZmulti Mini that can be connected, refer to the document "PNOZmulti System Expansion").
  • Page 9: Safety Regulations

    Do not open the housing or make any unauthorised modifications. Please make sure you shut down the supply voltage when performing maintenance work (e.g. exchanging contactors). Operating Manual PNOZ mmc2p 1002103-EN-02...
  • Page 10: Function Description

    Function description Function description Functions The product PNOZ mmc2p has a serial interface RS232 interface to Download the project Read the diagnostic data Set virtual inputs for standard functions Read virtual outputs for standard functions. Information on diagnostics can be found in the document "Communication Interfaces".
  • Page 11: Installation

    Damage due to electrostatic discharge! Electrostatic discharge can damage components. Ensure against discharge before touching the product, e.g. by touching an earthed, conductive sur- face or by wearing an earthed armband. Dimensions 100 (3,94") 22,5 (0.88") Operating Manual PNOZ mmc2p 1002103-EN-02...
  • Page 12: Connect The Base Unit And Expansion Modules

    Please refer to the document "PNOZmulti System Expansion" for details of the number of modules that can be connected to the base unit and the module types. Operating Manual PNOZ mmc2p 1002103-EN-02...
  • Page 13: Commissioning

    PNOZmulti Configurator. Proceed as described in the operat- ing instructions for the base unit. NOTICE For the commissioning and after every program change, you must check whether the safety devices are functioning correctly. Operating Manual PNOZ mmc2p 1002103-EN-02...
  • Page 14: Operation

    The LEDs “POWER”, “DIAG”, “FAULT”, “IFAULT” and “OFAULT” will light up on the base unit. The safety system PNOZmulti is ready for operation when the "POWER" and "RUN" LEDs on the base unit and the "POWER" LED on the PNOZ mmc2p are lit continuously. LED indicators Legend...
  • Page 15: Technical Details

    10,0 - 150,0 Hz Frequency Acceleration Shock stress EN 60068-2-27 In accordance with the standard Acceleration Duration 11 ms Max. operating height above sea level 2000 m Airgap creepage Overvoltage category Pollution degree Rated insulation voltage 30 V Operating Manual PNOZ mmc2p 1002103-EN-02...
  • Page 16 Spring-loaded terminals: Terminal points per connec- tion Stripping length with spring-loaded terminals 9 mm Dimensions Height 100,0 mm Width 22,5 mm Depth 120,0 mm Weight 85 g Where standards are undated, the 07/2010 latest editions shall apply. Operating Manual PNOZ mmc2p 1002103-EN-02...
  • Page 17: Order Reference

    Screw terminals PNOZ Screw terminals, 10 piece 793 539 mmc2p,mml1p 10 pcs. Terminator, jumper Product type Features Order No. PNOZ s terminator plug Terminator, yellow, 10 pieces 750 010 PNOZ s connector Jumper, 10 pieces 750 020 Operating Manual PNOZ mmc2p 1002103-EN-02...
  • Page 18 Front cover Support Technical support is available from Pilz round the clock. Americas Australia Scandinavia Brazil +61 3 95446300 +45 74436332 +55 11 97569-2804 Spain Canada Europe +34 938497433 +1 888-315-PILZ (315-7459) Austria Switzerland +41 62 88979-30 Mexico +43 1 7986263-0...