Wiring
7.7.3

Absolute encoder with SSI interface

If the cable length is > 50 m, please speak to our Customer Support.
Mini-I/O socket X41, Pin
Input circuit
Operating Manual PMCprimo C2
1004683-EN-02
8
6 4
2
1
2
3
7
5 3
1
4
5
6
7
8
---
n. c. = not connected
8
4
5
Shield
X40a
2
4
Designation
V+
0 V
n. c.
CLOCK
CLOCK
n. c.
DATA
DATA\
Shield
Encoder supply
Description
Supply voltage
Supply voltage 0 V
---
Pulse signal
Pulse signal inverted
---
Data
Data inverted
Shield
Absolute encoder with SSI
interface
Shielded
Shield connection in the
housing