Function description
4.1.6

Encoder

An encoder can be connected to the 9-pin D-Sub socket X41.
The following encoders are supported:
Incremental encoder with TTL signal
}
Absolute encoder with SSI interface
}
The encoder's supply voltage is connected to separate terminals on the device (X40/8,16).
The size of the voltage depends on the encoder (e.g. 5 V, 10 - 30 VDC).
4.1.7

Reset button

The "RESET" button is mounted in a recess on the front of the unit. It can only be accessed
using an appropriate tool (e.g. a pin).
The following actions can be triggered by pressing the "RESET" button:
Change from "Startup" operating status to "Boot Menu"
}
Hardware reset (cold start): Change from operating states "RUN" or "STOP" to "Star-
}
tup" (if a USB stick is inserted, any device data present will be copied, see Functions of
the reset button.)
Change from "RUN" operating status to "STOP"
}
Change from "STOP" operating status to "RUN"
}
Operating instructions PMCprimo C