Function description
5.1.5.6

USB

}
The USB interface is used for data exchange.
}
The data can contain a new firmware with a complete project.
}
Save data from a controller to a USB stick:
– Save data on a USB stick into the following directory: "\PILZ\primoBACKUP\"
}
To save, execute the SP11 command.
}
Save data for device exchange via reset button to USB stick:
– Make sure that the directory "primoBACKUP" does not exist on the USB stick. (avoid
– Insert USB stick
– Press the RESET button during the boot process until the LEDs flash blue.
}
Copy data stored on a USB stick to the controller:
– Insert USB stick
}
Activate the hardware reset (cold start) by pressing the "RESET" button, see Functions of
the reset button.
5.1.6

Encoder

An encoder can be connected to the Mini I/O socket X41.
The following encoders are supported:
}
Incremental encoder with TTL signal
}
Absolute encoder with SSI interface
The encoder's supply voltage is connected to separate terminals on the device (X40a/2,4).
The size of the voltage depends on the encoder (e.g. 5 V, 10 - 30 VDC).
5.1.7

Reset button

The "RESET" button is mounted in a recess on the front of the unit. It can only be accessed
using an appropriate tool (e.g. a pin).
The following actions can be triggered by pressing the "RESET" pushbutton:
}
Change from "Startup" operating status to "Boot Menu"
Operating Manual PMCprimo C2
1004683-EN-02
INFORMATION
Use a USB stick with FAT32 formatting.
overwriting accidentally)
INFORMATION
Refer to the chapter entitled
the supply voltage.
Wiring [
32]
for details of how to connect
| 25