Pilz PSS u2 ES 4IOL Operating Manual
Pilz PSS u2 ES 4IOL Operating Manual

Pilz PSS u2 ES 4IOL Operating Manual

Remote i/o system

Advertisement

Quick Links

PSS u2 ES 4IOL
Control system PSS u2
}
Remote I/O system PSS u2
}
Operating Manual-1004880-EN-01

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the PSS u2 ES 4IOL and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Pilz PSS u2 ES 4IOL

  • Page 1 PSS u2 ES 4IOL Control system PSS u2 Remote I/O system PSS u2 Operating Manual-1004880-EN-01...
  • Page 2 Preface This document is the original document. All rights to this documentation are reserved by Pilz GmbH & Co. KG. Copies may be made for the user's internal purposes. Suggestions and comments for improving this documenta- tion will be gratefully received.
  • Page 3: Table Of Contents

    Removing an electronic module 7.2.3 Changing an electronic module during operation Section 8 Wiring General wiring guidelines 8.1.1 Connection mechanism for terminal blocks Terminal configuration 8.2.1 Connection examples Section 9 Operation Display elements and messages Operating Manual PSS u2 ES 4IOL 1004880-EN-01...
  • Page 4 Contents Section 10 Technical details Section 11 Order reference 11.1 Product 11.2 Accessories Operating Manual PSS u2 ES 4IOL 1004880-EN-01...
  • Page 5: Introduction

    This operating manual explains the function and operation, describes the installation and provides guidelines on how to connect the product. This documentation is valid for the product PSS u2 ES 4IOL. It is valid until new document- ation is published.
  • Page 6 Introduction INFORMATION This gives advice on applications and provides information on special fea- tures. Operating Manual PSS u2 ES 4IOL 1004880-EN-01...
  • Page 7: Overview

    Up to 32 bytes of process data per port Up to 128 bytes of process data, including header, per module Device configuration saved in the master Energy-saving functions LEDs for: – IO-Link mode – Module error – Operating status Operating Manual PSS u2 ES 4IOL 1004880-EN-01...
  • Page 8: Safety

    Use of the module outside the areas described in this manual, Any use of the module that is not in accordance with the technical details. The module PSS u2 ES 4IOL may be used in conjunction with the following terminal block: 16-pin terminal block...
  • Page 9: Warranty And Liability

    Any type of modification has been made (e.g. exchanging components on the PCB boards, soldering work etc.). 3.3.3 Disposal When decommissioning, please comply with local regulations regarding the disposal of electronic devices (e.g. Electrical and Electronic Equipment Act). Operating Manual PSS u2 ES 4IOL 1004880-EN-01...
  • Page 10: Function Description

    IO-Link device with 2 Bytes of input data Port 1 IO-Link device with 2 Bytes of input data Process image of outputs Port 2 IO-Link device with 1 Byte of output data Empty Unused bytes, which are filled with zeros Operating Manual PSS u2 ES 4IOL 1004880-EN-01...
  • Page 11 "1": There is an IO-Link connection to the device. CQ input "0": There is a "0" signal at the configurable CQ input (terminal 2,6,10,14). "1": There is a "1" signal at the configurable CQ input (terminal 2,6,10,14). Operating Manual PSS u2 ES 4IOL 1004880-EN-01...
  • Page 12: Block Diagram

    "1": A "1" signal is output at the configurable CQ output (terminal 2,6,10,14). Block diagram n.c. n.c. Module IO-Link Port 0 IO-Link Port 3 Supply Data (ST) Periphery Supply +24 V DC Fig.: Block diagram PSS u2 ES 4IOL Operating Manual PSS u2 ES 4IOL 1004880-EN-01...
  • Page 13: Supply

    In order to configure the module in a PROFINET-enabled controller you will need to down- load and install the GSDML file from the PILZ website. The GSDM file contains IO-Link modules with the following process data lengths for the input and output data:...
  • Page 14: Reaction Time

    In this mode, the configuration is loaded from the device into the master. This setting can be used when devices already contain configured data and this data is to be ap- plied to the master. Operating Manual PSS u2 ES 4IOL 1004880-EN-01...
  • Page 15 Function description Download In this mode, the configuration saved in the master is written to the device. This setting can be used when a device needs to be exchanged. Operating Manual PSS u2 ES 4IOL 1004880-EN-01...
  • Page 16: Exchanging An Io-Link Device

    2. Connect the new device to the master module. The configuration saved in the master module is written to the device. INFORMATION Should the device already contain a configuration, this will be overwritten during any download. Operating Manual PSS u2 ES 4IOL 1004880-EN-01...
  • Page 17: Exchanging A Master

    7. In the IO-Link Configurator, select "Download" under "Save the device configuration". 8. Download the ST configuration to PASconfig so that the amended value is adopted. The PSS u2 system will be restarted. Operating Manual PSS u2 ES 4IOL 1004880-EN-01...
  • Page 18: Installation

    7.1.1 Dimensions The dimensions include the backplane, electronic module and terminal block. 12,5 51,1 111,1 Fig.: Dimensions in mm, including backplane, electronic module and terminal block Operating Manual PSS u2 ES 4IOL 1004880-EN-01...
  • Page 19: Inserting And Removing An Electronic Module

    Unforeseeable error reactions may be triggered if modules are inserted and removed under load. 7.2.1 Inserting an electronic module 1. Insert the electronic module into the suspen- sion lug on the back- plane. Operating Manual PSS u2 ES 4IOL 1004880-EN-01...
  • Page 20 3. Insert the terminal block into the suspen- sion lug on the module. 4. Swivel the terminal block upwards until you hear it click into place. Operating Manual PSS u2 ES 4IOL 1004880-EN-01...
  • Page 21: Removing An Electronic Module

    A new electronic module can be inserted during operation. Effects: Module bus communication between the other modules is not interrupted. The head module may need to be configured and restarted in order for the new module to be detected. Operating Manual PSS u2 ES 4IOL 1004880-EN-01...
  • Page 22: Wiring

    24 V+ voltage output for sensor/actuator L+ IO-Link communication CQ n.c. 0 V voltage output for sensor/actuator L- 24 V+ voltage output for sensor/actuator L+ IO-Link communication CQ n.c. 0 V voltage output for sensor/actuator L- Operating Manual PSS u2 ES 4IOL 1004880-EN-01...
  • Page 23: Connection Examples

    Wiring 8.2.1 Connection examples IO-Link Device Fig.: IO-Link device (Class A Port) Fig.: 1-channel sensor in DI mode Operating Manual PSS u2 ES 4IOL 1004880-EN-01...
  • Page 24 Wiring Fig.: 1-channel actuator in DO mode Operating Manual PSS u2 ES 4IOL 1004880-EN-01...
  • Page 25 Fig.: IO-Link device with additional supply (Class B Port). The supply voltage module PSS u2 ES PSP forms a new supply group for the additional supply to the IO-Link devices. The additional supply for the device is tapped from the shunt module PSS u2 ES 8PTD 24V 0V. Operating Manual PSS u2 ES 4IOL 1004880-EN-01...
  • Page 26: Operation

    State Meaning - - - Module is not in operation Green Module ready for operation Green Module in operation Module was inserted in the wrong slot. Internal error Temperature warning: Too warm (1) Operating Manual PSS u2 ES 4IOL 1004880-EN-01...
  • Page 27 "too warm" threshold value, the module will switch to an error-free state. Terminal status display L+n (terminal 1, 5, 9, 13) Colour State Meaning - - - 24 V not present at terminal L+ Green 24 V present at terminal L+ Operating Manual PSS u2 ES 4IOL 1004880-EN-01...
  • Page 28 Green DI mode: There is a "1" signal at the input DO mode: There is a "1" signal at the output Legend LED on LED flashes LED flashes briefly LED off Operating Manual PSS u2 ES 4IOL 1004880-EN-01...
  • Page 29 60068-2-30, EN 60068-2-78 Ambient temperature In accordance with the standard EN 60068-2-14 0 - 55 °C Temperature range Storage temperature In accordance with the standard EN 60068-2-1/-2 -40 - 70 °C Temperature range Operating Manual PSS u2 ES 4IOL 1004880-EN-01...
  • Page 30 Mounting area (e.g. control cabinet) IP54 Mechanical data Material Housing Mounting type plug-in Dimensions Height 110,8 mm Width 12,5 mm Depth 72,5 mm Where standards are undated, the 2017-07 latest editions shall apply. Operating Manual PSS u2 ES 4IOL 1004880-EN-01...
  • Page 31 PSS u2 A CE T (10 pc.) Coding strip, 10 pieces 328 861 Backplanes Product type Features Order no. PSS u2 B 1 Backplane, 1 slot 328 811 PSS u2 B 4 Backplane, 4 slots 328 810 Operating Manual PSS u2 ES 4IOL 1004880-EN-01...
  • Page 32 Front cover Support Technical support is available from Pilz round the clock. Americas Australia Scandinavia +45 74436332 Brazil +61 3 95600621 +55 11 97569-2804 Spain Canada Europe +34 938497433 +1 888-315-PILZ (315-7459) Austria Switzerland Mexico +43 1 7986263-0 +41 62 88979-30...

This manual is also suitable for:

Pss u2

Table of Contents