Technical details
Ethernet interface
Transmission rate
Potential isolation
EtherCAT interface
Quantity
Connection
Transmission rates
Potential isolation
Environmental data
Climatic suitability
Ambient temperature
In accordance with the standard EN 60068-2-14
Temperature range
Storage temperature
In accordance with the standard EN 60068-2-1/-2
Temperature range
Climatic suitability
In accordance with the standard EN 60068-2-78
Humidity
Condensation during operation
Max. operating height above sea
level
EMC
Vibration
In accordance with the standard EN 60068-2-6
Frequency
Amplitude
Acceleration
Shock stress
In accordance with the standard EN 60068-2-27
Acceleration
Duration
Cooling
Airgap creepage
In accordance with the standard EN 61131-2
Overvoltage category
Pollution degree
Protection type
In accordance with the standard EN 60529
Housing
Terminals
Mounting area (e.g. control cab-
inet)
Potential isolation
Potential isolation between
Operating Manual PMCprimo C2
1004683-EN-02
680180
1 Gbit/s
yes
680180
1
RJ45
100 MBit/s
yes
680180
EN 60068-2-1, EN 60068-2-14, EN
60068-2-2, EN 60068-2-78
0 - 40 °C
-40 - 70 °C
93 % r. h. at 40 °C
Not permitted
2000 m
EN 61131-2
5 - 8,4 Hz
3,5 mm
10 m/s²
150 m/s²
11 ms
Built-in fan
II
2
IP20
IP20
IP54
680180
Encoder and system voltage
680190
1 Gbit/s
yes
680190
1
RJ45
100 MBit/s
yes
680190
EN 60068-2-1, EN 60068-2-14, EN
60068-2-2, EN 60068-2-78
EN 60068-2-14
0 - 40 °C
EN 60068-2-1/-2
-40 - 70 °C
EN 60068-2-78
93 % r. h. at 40 °C
Not permitted
2000 m
EN 61131-2
EN 60068-2-6
5 - 8,4 Hz
3,5 mm
10 m/s²
EN 60068-2-27
150 m/s²
11 ms
Built-in fan
EN 61131-2
II
2
EN 60529
IP20
IP20
IP54
680190
Encoder and system voltage
| 69