Commissioning
The motion controller reports on the configuration, once the Ethernet connection has been
established.
0.1:
0.1:
hw1
0.1
SOFTWARE
Firmware
Motion:
IEC PLC:
Interpolation:
ETHERNET
IP address
Netmask
Gateway
CHANNELS
Number
HARDWARE
Type:
Item No.:
Ser. No.:
Pr. Ver.:
Encoder
Inputs:
Outputs:
Virtual inputs:
Virtual outputs:
Analogue inputs:
Analogue outputs: 0
DEVICES in EtherCAT Network:
PMC SC6A062R at EtherCAT ADDR 1001 found (DS402)
PMC SC6A261R at EtherCAT ADDR 1002 found (DS402)
PMCprotego D (S701) at EtherCAT ADDR 1003 found (DS402)
Operating Manual PMCprimo C2
1004683-EN-02
03.06.01.00, Nov 19 2020, 12:01:18
NOT INSTALLED
INSTALLED
NOT INSTALLED
172.23.10.141
255.255.248.0
192.168.0.1
1...60
PMCprimo C2 1300MHz unknown
680190
111111
1.0
0
8
8
56
56
0
Inputs:
18
Outputs: 10
Virtual
4
inputs: