Pilz PNOZ m ES CC-Link Operating Manual
Pilz PNOZ m ES CC-Link Operating Manual

Pilz PNOZ m ES CC-Link Operating Manual

Configurable control systems pnozmulti 2

Advertisement

PNOZ m ES CC-Link
}
Configurable control systems PNOZmulti 2
Operating Manual-1003817-EN-02

Advertisement

Table of Contents
loading

Summary of Contents for Pilz PNOZ m ES CC-Link

  • Page 1 PNOZ m ES CC-Link Configurable control systems PNOZmulti 2 Operating Manual-1003817-EN-02...
  • Page 2 Preface This document is a translation of the original document. All rights to this documentation are reserved by Pilz GmbH & Co. KG. Copies may be made for internal purposes. Suggestions and comments for improving this documentation will be gratefully received.
  • Page 3: Table Of Contents

    Commissioning General wiring guidelines Connecting the supply voltage Interface assignment Download modified project to the PNOZmulti system Connection example Section 7 Operation Messages Section 8 Technical Details Section 9 Order reference Product Accessories Operating Manual PNOZ m ES CC-Link 1003817-EN-02...
  • Page 4: Operating Manual Pnoz M Es Cc-Link

    Introduction Introduction Validity of documentation This documentation is valid for the product PNOZ m ES CC-Link. It is valid until new docu- mentation is published. This operating manual explains the function and operation, describes the installation and provides guidelines on how to connect the product.
  • Page 5 Introduction INFORMATION This gives advice on applications and provides information on special fea- tures. Operating Manual PNOZ m ES CC-Link 1003817-EN-02...
  • Page 6: Overview

    128 virtual inputs and outputs on the control system PNOZmulti can be defined in the PNOZmulti Configurator for communication with the fieldbus CC-Link. Max. 1 PNOZ m ES CC-Link can be connected to the base unit Plug-in connection terminals: either spring-loaded terminal or screw terminal available as an accessory (see order reference) Please refer to the document "PNOZmulti System Expansion"...
  • Page 7: Front View

    Overview Front view Legend: CC-Link interface X4: 0 V, 24 V: Supply connections Functional earth Rotary switch For setting the station addresses LEDs: Power, Run, L Err Operating Manual PNOZ m ES CC-Link 1003817-EN-02...
  • Page 8: Safety

    Safety Safety Intended use The fieldbus module PNOZ m ES CC-Link is an expansion module of the configurable con- trol system PNOZmulti. It is used for communication between the configurable control sys- tem PNOZmulti and the CC-Link . CC-Link is designed for fast data exchange at field level. The expansion module CC-Link is a passive subscriber (Slave) in CC-Link.
  • Page 9: Safety Regulations

    Do not open the housing or make any unauthorised modifications. Please make sure you shut down the supply voltage when performing maintenance work (e.g. exchanging contactors). Operating Manual PNOZ m ES CC-Link 1003817-EN-02...
  • Page 10: Function Description

    PNOZmulti Configurator. The base unit and the fieldbus module PNOZ m ES CC-Link are connected via a jumper. After the supply voltage is switched on or the PNOZmulti control system is reset, the fieldbus module PNOZ m ES CC-Link is con- figured and started automatically.
  • Page 11 RX(m+50)n o87 o86 o85 o84 o83 o82 o81 o80 Word addressed output data o88 - o127 High byte Low byte Bit No. RWr l RWr l RWr l Operating Manual PNOZ m ES CC-Link 1003817-EN-02...
  • Page 12: Led Status

    PNOZmulti 2 answers as follows: High Byte Low Byte RWr (l+3) Segment number Table number RWr(l+4) Segment Byte 1 Segment Byte 0 RWr(l+5) Segment Byte 3 Segment Byte 2 RWr(l+6) Segment Byte 5 Segment Byte 4 Operating Manual PNOZ m ES CC-Link 1003817-EN-02...
  • Page 13: Block Diagram

    Segment Byte 6 RWr(l+8) Segment Byte 9 Segment Byte 8 RWr(l+9) Segment Byte 11 Segment Byte 10 RWr(l+A) Reserved Segment Byte 12 RWr(l+B) Reserved Reserved Block diagram 24 V Module CC-Link Supply FG/PE Data (ST) Operating Manual PNOZ m ES CC-Link 1003817-EN-02...
  • Page 14: Installation

    Connect the base unit and the expansion module as described in the operating instructions for the base units. Connect the black/yellow terminator to the expansion module. Install the expansion module in the position in which it is configured in the PNOZmulti Configurator. Operating Manual PNOZ m ES CC-Link 1003817-EN-02...
  • Page 15 Please refer to the document "PNOZmulti System Expansion" for details of the number of modules that can be connected to the base unit and the module types. Operating Manual PNOZ m ES CC-Link 1003817-EN-02...
  • Page 16: Commissioning

    Connect the supply voltage to the fieldbus module: 24 V terminal: + 24 VDC 0 V terminal: 0 V Protect the supply voltage as follows: – Circuit breaker, characteristic C - 6 A – Blow-out fuse, slow, 6A Operating Manual PNOZ m ES CC-Link 1003817-EN-02...
  • Page 17: Interface Assignment

    PNOZmulti Configurator. Proceed as described in the operat- ing instructions for the base unit. NOTICE For the commissioning and after every program change, you must check whether the safety devices are functioning correctly. Operating Manual PNOZ m ES CC-Link 1003817-EN-02...
  • Page 18: Connection Example

    Commissioning Connection example PNOZ m ES CC-Link Operating Manual PNOZ m ES CC-Link 1003817-EN-02...
  • Page 19: Operation

    When the supply voltage is switched on, the PNOZmulti safety system copies the configur- ation from the chip card. The LEDs “POWER”, “DIAG”, “FAULT”, “IFAULT” and “OFAULT” will light up on the base unit. The expansion module PNOZ m ES CC-Link is configured and started automatically. Messages Legend LED on...
  • Page 20: Technical Details

    In accordance with the standard EN 60068-2-1/-2 Temperature range -25 - 70 °C Climatic suitability In accordance with the standard EN 60068-2-30, EN 60068-2-78 Condensation during operation Not permitted Max. operating height above sea level 2000 m Operating Manual PNOZ m ES CC-Link 1003817-EN-02...
  • Page 21 0,5 Nm Conductor cross section with spring-loaded terminals: Flexible with/without crimp connector 0,2 - 2,5 mm², 24 - 12 AWG Spring-loaded terminals: Terminal points per connec- tion Stripping length with spring-loaded terminals 9 mm Operating Manual PNOZ m ES CC-Link 1003817-EN-02...
  • Page 22 Technical Details Mechanical data Dimensions Height 101,4 mm Width 22,5 mm Depth 110,4 mm Weight 90 g Where standards are undated, the 2015-08 latest editions shall apply. Operating Manual PNOZ m ES CC-Link 1003817-EN-02...
  • Page 23: Order Reference

    Screw terminals Screw terminals, 10 pieces 793 543 PNOZ mmcxp 10 pcs. Terminator, jumper Product type Features Order No. PNOZ mm0.xp connector Jumper yellow/black to connect the modules, 10 piece 779 260 left Operating Manual PNOZ m ES CC-Link 1003817-EN-02...
  • Page 24 Back cover Support Technical support is available from Pilz round the clock. Americas Australia Scandinavia Brazil +61 3 95600621 +45 74436332 +55 11 97569-2804 Spain Canada Europe +34 938497433 +1 888-315-PILZ (315-7459) Austria Switzerland Mexico +43 1 7986263-0 +41 62 88979-30...