Configure Trigger, Exposure, and Line Rate Settings

This section describes how to control the exposure time with or without external triggers.
Note: For the detailed setting information, see
Line Rate
Settings.

Control via External Triggers

When Controlling the Exposure Time Using Specified Exposure Times
1. First, configure the RGB channels. Set Exposure Mode to Timed. (Timed = Default).
2. Specify the Exposure Time in Exposure Time. For the RGB channels, you must configure
each R, G, and B channel individually.
3. Set Trigger Mode to On.
4. Configure the Trigger Source and Trigger Activation settings if necessary.
5. Second, configure the SWIR channel. Repeat steps 1 through 4 to configure.

Control Without External Triggers

When Controlling the Exposure Time Using Specified Exposure Times
1. First, configure the RGB channels. Set Exposure Mode to Timed. (Timed = Default).
2. Set Trigger Mode to Off. (Off = Default)
3. Specify a line period slower than the exposure time in Acquisition Line Rate.
4. Specify the Exposure Time in Exposure Time. For the RGB channels, you must configure
each R, G, and B channel individually.
5. Second, configure the SWIR channel. Repeat steps 1 through 4 to configure.
When Not Controlling the Exposure Time
1. First, configure the RGB channels. Set Exposure Mode to Off. (Off =Default)
The exposure will be performed with an exposure time equal to 1 / line rate.
Note: The exposure time specified in ExposureTime will be disabled.
2. Second, configure the SWIR channel. Repeat step 1 to configure.
Short ASCII Commands for Trigger, Exposure,