Digitaliocontrol - JAI SW-4010Q-MCL-M52 User Manual

Rgb color & swir prism line scan camera with mini camera link interface
Table of Contents

Advertisement

SW-4010Q-MCL-M52 User Manual (Tentative)

DigitalIOControl

Configure settings for digital input/output.
Related Topic:
GPIO (Digital Input/Output Settings)
Digital IO Control Item
LineSelector
LineMode
LineInverter
LineStatus
Setting
Default
Range
Value
-
5: Idle
-
-
0: False
0: False
1: True
0: False
(Low)
0: False
1: True
(High)
Select the input/output to configure.
0: Line1 TTL Out1
3: Line4 TTL In1
4: Line5 Opt In1
5: Idle
7: Line8 TTL Out2
8: Line9 TTL Out3
9: Line10 TTL In2
11: Line12 TTL Out4
12: Line13 TTL In3
13: Nand0 In1
14: Nand0 In2
15: Nand1 In1
16: Nand1 In2
Display the input/output status (whether it is input or output).
0:Input (LineSelector=3,4,9,12,13,14,15,16)
2:Output (LineSelector=0,7,8,11)
Enable/disable polarity inversion for the selected input signal or output
signal.
Note: LineSelector=3, 4, 9, 12 are fixed to "0".
Display the status of the input signal or output signal (True: High, False:
Low).
- 80 -
Description
12pin Connector
AUX Connector
12pin Connector
AUX Connector
Setting List

Advertisement

Table of Contents
loading

Table of Contents