SW-4010Q-MCL-M52 User Manual (Tentative)
SWIR
Item
SWIRExposureMode
SWIRExposureTime
SWIRTriggerMode
SWIRTriggerSource
SWIRTriggerActivation
SWIRAcquisitionLineRate
Short ASCII
Command
0: Off
IRTR
1: Timed (Default)
136 (Default) ~ 13306 (Unit:
IRPE
149.9ns)
0: Off (Default)
IRTG
1: On
0: Low
1: High
10-13: PulseGenerator0-3
14-17: UserOutput0-3
20: Line4 TTL In1 (Default)
21: Line5 Opt In1
IRTI
23: Liune7 CC1
24: Line10 TTL In2
26: NAND0 Out
27: NAND1 Out
28: Line13 TTL In3
29: EncoderTrigger
1:Rising Edge
IRTP
2:Falling Edge (Default)
170 (Default) ~ 13340 (Unit:
IRLR
149.9ns)
Values
IRTR=[Param.]<CR><LF>
IRTR?<CR><LF>
IRPE=[Param.]<CR><LF>
IRPE?<CR><LF>
IRTG=[Param.]<CR><LF>
IRTG?<CR><LF>M
IRTI=[Param.]<CR><LF>
IRTI?<CR><LF>M
IRTP=[Param.]<CR><LF>
IRTP?<CR><LF>M
IRLR=[Param.]<CR><LF>
IRLR?<CR><LF>
Use this command to set the line rate of the camera
by specifying the line period. The unit value is
1/100us.