Prnu Correction (Pixel Gain Correct) - JAI SW-4010Q-MCL-M52 User Manual

Rgb color & swir prism line scan camera with mini camera link interface
Table of Contents

Advertisement

SW-4010Q-MCL-M52 User Manual (Tentative)

PRNU Correction (Pixel Gain Correct)

PRNU (photo response non-uniformity) is a variation between pixels generated by the sensor
under bright conditions. If the line rate is slowed or a long exposure time is set, the dark current in
the sensor may change and the state of the PRNU may change.
RGB
1. Specify the user area (User1 ~ User3) to save the gain correction value with
PixelGainCorrectionMode.
Note: You cannot perform calibration when Off or Default is selected.
2. Gain correction data is automatically generated by PerformPixelGainCalibration and
saved in the user area specified in step 1.
3. You can check the execution result of gain correction by PixelGainDetectResult.
For more information, see the following Short ASCII command table.
Item
PixelGainCorrectionMode
PerformPixelGainCalibration PGR
PixelGainDetectResult
Short ASCII
Values
Command
0:Off
1:Default (Default)
PGC
2:User1
3:User2
4:User3
1: Succeeded
2: Image too bright
PGS
3: Image too dark
4: Timeout error
Command Examples
PGC=[Param.]<CR><LF>
PGC?<CR><LF>
Note: Default stores correction data with factory settings.
-
PGR<CR><LF>
PGS?<CR><LF>