SW-4010Q-MCL-M52 User Manual (Tentative)

Adjust the White Balance

Adjust the white balance using the automatic adjustment function.
Note: The white balance function is only supported on RGB channels.
1. Place a white sheet of paper or similar object under the same lighting conditions as the
intended subject, and zoom in to capture the white.
White objects near the subject, such as a white cloth or wall, can also be used. Be sure to
prevent the high-intensity spotlights from entering the screen.
2. Set BalanceWhiteAuto to Once. The white balance is automatically adjusted.
For more information, see the following Short ASCII command table.
Item
BalanceWhiteAuto

Step 6: Configure Various Other Settings

See
"Setting
List" or "SW-4010Q-MCL-M52 Command List" (available from the JAI website) to
configure settings as necessary.
Note: We recommend performing DSNU and PRNU calibration again whenever the line rate
setting is changed significantly.
Short ASCII
Values
Command
0:Off (Default)
2:Once
4:Exposure Once
AWB
5:Preset 5000K
6:Preset 6500K
7:Preset 7500K
Command Examples
AWB=[Param.]<CR><LF>
AWB?<CR><LF>
- 34 -