ExposureActive Function

Related Setting Items: AcquisitionControl,
Perform external output for the timing at which video is accumulated to the sensor.
The signal is output to the DC IN / TRIG IN connector (12-pin round) and the DIGITAL I/O-1 video
output connector (Camera Link).
Example: Output to the DIGITAL I/O-1 video output connector (Camera Link)
Note: The negative polarity is output to the DC IN / trigger IN connector (12-pin round), and
the positive polarity is output to the DIGITAL I/O 1 video output connector (Camera Link). The
polarities cannot be changed.

Test Pattern Function

Related Setting Items: ImageFormatControl,
You can display the following test patterns. Video output is not possible while a test pattern is
being executed. This function is not dependent on gain and offset values that have already been
configured, and output is performed in the following states.
Channel
RGB
White, GreyPattern1(Ramp), GreyPattern2(Stripe), ColorBar
SWIR
GreyHorizontalRamp, GreyScale2, White
SWIRAcquisitionControl
SWIRImageFormatControl