CounterAndTimer
Control Item
CounterStatus

EncoderControl

Configure the rotary encoder related settings.
Related Topic:
Connecting Rotary Encoders
Encoder Control Item
EncoderSourceA
EncoderSourceB
EncoderDivider
EncoderAveragingInterval
EncoderFilter (cycle)
EncoderStrobe (ns)
Setting
Default
Range
Value
0:
-
CounterIdle
Setting
Default
Range
Value
Select where to input the signal from the rotary encoder.
0: Line5 Opt In1
0: Line5
-
1: Line4 TTL In1
Opt In1
2: Line10 TTL In2
3: Line13 TTL In3
Select where to input the signal from the rotary encoder
0: Line5 Opt In1
0: Line5
-
1: Line4 TTL In1
Opt In1
2: Line10 TTL In2
3: Line13 TTL In3
1 ~
Set the number of triggers to be generated during one pitch of the rotary encoder.
32bit
65536
The number of triggers is 65536 / (set value).
max
Perform the internal processing by averaging the time interval of the specified
number of signals.
0: none
1: 2 pulses
-
0: none
2: 4 pulses
3: 8 pulses
4: 16 pulses
5: 32 pulses
Apply a low-pass filter to prevent noise on the signal from the rotary encoder and
stabilize the signal for the specified number of cycles.
0 ~ 15
0
Note: 10ns/cycle
Set the strobe length of the Trigger signal generated from the rotary encoder by the
1 ~ 256 1
number of cycles.
Display the counter status.
0: CounterIdle
2: CounterActive
4: CounterOverflow - Count value exceedded the maximum value.