Counterandtimercontrol - JAI SW-4010Q-MCL-M52 User Manual

Rgb color & swir prism line scan camera with mini camera link interface
Table of Contents

Advertisement

SW-4010Q-MCL-M52 User Manual (Tentative)

CounterAndTimerControl

Configure counter settings.
Note: This camera only supports the counter functions.
Related Topic:
Counter and Timer Control Function
CounterAndTimer
Control Item
CounterSelector
CounterEventSource
CounterEventActivation
CounterReset Source
CounterResetActivation
CounterReset
CounterRefresh
CounterValue
Setting
Default
Range
Value
0: Counter0
-
0: Off
0:Rising Edge
-
-
-
-
-
-
-
-
-
0 - 32bit max 0
Select the counter.
0 - 7: Counter0 - 7
Assign the Counter Event signal for which you want to read the
count value to a dedicated counter and read the value.
0: Off
1: Line Trigger (Counter0 only)
2: Exposure Start (Counter2 only)
3: Line Start (Counter1 only)
4: Line Transfer End (Counter3 only)
5: SWIR Line Trigger (Counter4 only)
6: SWIR Exposure Start (Counter6 only)
7: SWIR Line Start (Counter5 only)
8: SWIR Line Transfer End (Counter7 only)
Display the count timing. The setting value is fixed to Rising Edge.
Specify the source to reset the counter. This source triggers the
counter to reset.
0: Software
3: Line4 TTL In1
4: Line5 Opt In1
9: Line10 TTL In2
12: Line13 TTL In3
Select the timing to reset the counter.
1: Rising Edge
2: Falling Edge
3: Level High
4: Level Low
Reset the counter.
Note: Available only when CounterResetSource is set to Software.
Update the counter.
Display the count value.