Short ASCII Commands for Trigger, Exposure, Line Rate Settings

This section shows the short ASCII commands to configure the Trigger, Exposure, and Line Rate
settings.
RGB
Item
ExposureMode
ExposureTime
TriggerMode
TriggerSource
TriggerActivation
AquisitionLineRate
Short ASCII
Command
0: Off
TR
1: Timed (Default)
Red: PER
300 ~ 1514907 (Default)
Green: PEG
[100 = 1us]
Blue: PEB
0: Off (Default)
TM
1: On
0: Low
1: High
10-13: PulseGenerator0-3
14-17: UserOutput0-3
20: Line4 TTL In1 (Default)
21: Line5 Opt In1
TI
23: Line7 CC1
24: Line10 TTL In2
26: NAND0 Out
27: NAND1 Out
28: Line13 TTL In3
29: EncoderTrigger
1:Rising Edge
TA
2:Falling Edge (Default)
4855 ~ 200000 (Default)
LR
[100 = 1us]
Values
TR=[Param.]<CR><LF>
TR?<CR><LF>
Varies depending on the ClConfiguration and
CameraLinkClockFrequency settings.
When setting the Red channel:
PER=[Param.]<CR><LF>
PER?<CR><LF>
TM=[Param.]<CR><LF>
TM?<CR><LF>M
TI=[Param.]<CR><LF>
TI?<CR><LF>M
TA=[Param.]<CR><LF>
TA?<CR><LF>M
LR=[Param.]<CR><LF>
LR?<CR><LF>
Use this command to set the line rate of the camera
by specifying the line period. The unit value is
1/100us.