Variable Line Rate

Related Setting Items: AcquisitionControl,
You can set the line rate to 1L or more.
This function can be used to match the scanning speed of the camera to the feeding speed of the
object or to lengthen the accumulation time to increase sensitivity.
Width = 4096
RGB8: 500 ~ 20.5kHz
RGB10/12: 500 ~ 13.7kHz
Variable
Range
Width = 2048
RGB8: 500 ~ 40.8kHz
RGB10/12: 500 ~ 27.3kHz
Variable Unit 0.1Hz
Exposure Mode = OFF / TriggerMode = Off
Supported
Mode
ExposureMode = Timed / TriggerMode = Off
Notes:
You can also save the setting, and have it applied whenever the power is subsequently
l
turned on, but this requires addition operations.
Switching and settings storage for this function is performed via serial communication.
l
The black level will change depending on the line rate, so be sure to readjust the black
l
level after changing the line rate or trigger period.
SWIRAcquisitionControl
RGB
- 58 -
SWIR
500 Hz ~ 39.2kHz