SW-4010Q-MCL-M52 User Manual (Tentative)
Electronic Shutter
Related Setting Items: AcquisitionControl,
How to Compensate Lateral Chromatic Aberration
When you use this function, you can set the exposure to a preconfigured accumulation time,
regardless of the line rate.
Variable Range
Variable Unit
Supported Operation Mode
Caution:
In "Trigger Mode Off, Exposure Mode Timed" mode, the line rate configured will be
the maximum value at which the shutter operates. However, in "Trigger Mode ON, Exposure
Mode Timed" mode, the input trigger period will be the maximum value.
Notes:
The exposure offset duration for the RGB channels is -0.85 μs. The SWIR channel does
l
not have exposure offset duration.
You can also save the setting, and have it applied whenever the power is subsequently
l
turned on, but this requires additional operations.
Switching and settings changing and storage for this function is performed via serial
l
communication.
SWIRAcquisitionControl
RGB
3 μs ~ 15149.07 μs
0.01μs (1clk)
Trigger Mode = On / Off
Exposure Mode = Timed
- 59 -
Main Functions
SWIR
20.38 μs (1L) ~ 1994.90 μs
0.1499 μs (1clk)