② Mounting; ③ Camera Link Cable; ④ Frame Grabber Board; ⑤ Aux Cable (10 Pin) (Option) - JAI SW-4010Q-MCL-M52 User Manual

Rgb color & swir prism line scan camera with mini camera link interface
Table of Contents

Advertisement

SW-4010Q-MCL-M52 User Manual (Tentative)
② Mounting
When mounting the camera directly to a wall or other device, use screws that match the mounting
holes on the camera (M4: depth 6mm).
Caution:
For heavy lenses, be sure to support the lens itself. Do not use configurations in
which its weight is supported by the camera.
③ Camera Link Cable
Connect the Camera Link cables to the DIGITAL I/O-1 and DIGITAL I/O-2 video output
connectors.
Use Cable Link compatible cables.
l
Refer to the specifications of the cable for details on its bend radius.
l
Caution:
Refer to
the connectors.
Note: The maximum Camera Link cable length is 10 m. The maximum length of cable you
can use will also vary depending on type and maker. If the CableEmphasis setting of
TransportLayerControl
lengthen the Camera Link cable.
④ Frame Grabber Board
Refer to the operating instructions of the frame grabber board and configure settings on the
computer as necessary. (Use a computer that meets the requirements of your frame grabber
board).
⑤ AUX Cable (10 Pin) (Option)
Performs external I/O such as trigger input.
⑥ DC IN / Trigger IN Connection Cable
Performs external I/O such as power supply and trigger input.
⑦ AC Adapter (Power Supply)
Connect the AC adapter and the round connector of the connection cable to the DC IN / Trigger IN
connector on the camera.
Notes on Camera Link Cable Connections
is changed from Normal to Medium or Strong, it may be possible to
when connecting the cables to
- 21 -
Preparation

Advertisement

Table of Contents
loading

Table of Contents