SW-4010Q-MCL-M52 User Manual (Tentative)
To Use the Counter Function
Configure the settings as follows.
Eight counters are available. Specify a counter (Counter0 to Counter7), and configure the
settings.
Item
Counter 0 ~ 7
CounterEventSource
Note: On this camera, the counter event activation is fixed to RisingEdge.
Setting Value
Selectable Range
Counter 0 ~ 7
Counter0: Off, Line Trigger
Counter1: Off, Line Start
Counter2: Off, Exposure Start
Counter3: Off, Line Transfer End
Counter4: Off, SWIR Line Trigger
Counter5: Off, SWIR Line Start
Counter6: Off, SWIR Exposure Start
Counter7: Off, SWIR Line Transfer End
- 65 -
Main Functions
Description
Select the counter.
Select the Counter Event
signal for which to read the
count value.
When set to Off, the
counter operation will stop
(but will not be reset).