Indication
Description
IEC 61850 Communi-
Communication via protocol IEC
cation OK
61850 is correct.
Settings Load
Starting to change the parameters
of the passive set of parameters.
Settings Check
The passive set of parameters is to
be activated; the internal param-
eter check is running.
Settings Activate
The passive set of parameters is
enabled and the device works with
these parameters.
Limit Violation x
Indication that a parameterized
limiting value has been violated
Indication 1 from
Status of the indications that can
Remote
be set to control the LEDs and the
binary outputs via the communica-
Indication 2 from
tion.
Remote
Indication x from
Status of any indications which can
Remote
be set for control via communica-
tion.
Binary Input 1
Indication of the logic state of the
binary input (ON/OFF)
Binary Input 2
Rotating Field Clock-
Indication of rotation voltage
wise
Group indication x
Up to 4 single-point indications can
be linked logically and combined to
a group indication.
Voltage Event Avail-
Indication of a voltage event
able
Volt. Unbalance Event
Indication of a voltage unbalance
Available
event
SICAM, SICAM Q100 7KG95xx, Manual
E50417-H1040-C522-A9, Edition 06.2021
Operational Indications and Operating Parameters
Notes
Indication ON: At least one message was received during
the set monitoring time. The time stamp is set when the
first valid message is received.
Indication OFF: No message was received during the set
monitoring time.
Indication ON: Start of changes
Indication OFF: Changes complete
Indication ON: Check started
Indication OFF: Check complete
Indication ON: Activation started
Indication OFF: Activation complete
Indication ON: The limit of the monitored measured value
has been violated or no measured value is parameterized as
input of the limiting value.
Indication OFF: The limit of the monitored measured value
is not violated.
Message invalid: The monitored measured value is invalid
(for example, frequency at V < 15 % of V
x = 1 to 16
Indication ON: ON
Indication OFF: OFF
Message invalid: Not yet updated via the communication or
again invalid via the communication
Indication ON
Indication OFF
Message invalid: Not yet updated via the communication or
again invalid via the communication.
x = 3 to 14
Indication invalid: in startup not updated
Binary input high: ON (OFF if inverted)
Binary input low: OFF (ON if inverted)
If the binary input has not been set to a function (load
profile, tariff TOU), a change is logged as an operational
indication; otherwise not, according to factory setting (can
be set).
Indication ON: Phase sequence Va-Vb-Vc, rotation clockwise
Indication OFF: Phase sequence Va-Vc-Vb, (2 phases inter-
changed); rotation counter-clockwise
Indication invalid: Direction of rotation cannot be calcu-
lated (for example, no voltage applied)
A total of 4 group indications can be parameterized.
x = 1 to 4