Siemens SICAM Q200 7KG97 Manual

Siemens SICAM Q200 7KG97 Manual

Class a power quality instrument and power monitoring device
Hide thumbs Also See for SICAM Q200 7KG97:

Advertisement

Quick Links

SICAM
Class A Power Quality
Instrument and Power
Monitoring Device SICAM
Q200 7KG97
OPC UA PubSub (MQTT)
Data Points
V02.50
Manual
E50417-H1040-C621-A2
Preface
Open Source Software
Table of Contents
Data-Points Mapping
Literature
1

Advertisement

Table of Contents
loading

Summary of Contents for Siemens SICAM Q200 7KG97

  • Page 1 Preface Open Source Software Table of Contents SICAM Data-Points Mapping Class A Power Quality Literature Instrument and Power Monitoring Device SICAM Q200 7KG97 OPC UA PubSub (MQTT) Data Points V02.50 Manual E50417-H1040-C621-A2...
  • Page 2 Edition: 01.2020 SIPROTEC™, DIGSI™, SIGRA™, SIGUARD™, SAFIR™, SICAM™, Version of the product described: V02.50 and MindSphere™ are trademarks of Siemens. Any unau- thorized use is prohibited. All other designations in this document may represent trademarks whose use by third parties for their own purposes may violate the proprietary...
  • Page 3: Preface

    Inquiries regarding individual training courses should be addressed to our Training Center: Siemens AG Phone: +49 (911) 433-7415 Siemens Power Academy TD Fax: +49 (911) 433-7929 Humboldtstrasse 59 E-mail: poweracademy@siemens.com SICAM, Class A Power Quality Instrument and Power Monitoring Device SICAM Q200 7KG97, Manual E50417-H1040-C621-A2, Edition 01.2020...
  • Page 4 Comply with all instructions, in order to avoid property damage. ² NOTE Important information about the product, product handling or a certain section of the documentation which must be given attention. SICAM, Class A Power Quality Instrument and Power Monitoring Device SICAM Q200 7KG97, Manual E50417-H1040-C621-A2, Edition 01.2020...
  • Page 5: Open Source Software

    License Conditions provide for it you can order the source code of the Open Source Software from your Siemens sales contact – against payment of the shipping and handling charges – for a period of at least 3 years after purchase of the product. We are liable for the product including the Open Source Software contained in it pursuant to the license conditions applicable to the product.
  • Page 6 SICAM, Class A Power Quality Instrument and Power Monitoring Device SICAM Q200 7KG97, Manual E50417-H1040-C621-A2, Edition 01.2020...
  • Page 7: Table Of Contents

    Measured Values.......................15 Harmonics........................18 Measured Values (Min.)....................20 Measured Values (Max.)....................23 Harmonics (Max.)......................26 1.10 Energy Values........................28 1.11 Security Counters......................30 Literature..............................31 SICAM, Class A Power Quality Instrument and Power Monitoring Device SICAM Q200 7KG97, Manual E50417-H1040-C621-A2, Edition 01.2020...
  • Page 8 SICAM, Class A Power Quality Instrument and Power Monitoring Device SICAM Q200 7KG97, Manual E50417-H1040-C621-A2, Edition 01.2020...
  • Page 9: Data-Points Mapping

    Introduction Indications Voltage Variations Transient Events Measured Values Harmonics Measured Values (Min.) Measured Values (Max.) Harmonics (Max.) 1.10 Energy Values 1.11 Security Counters SICAM, Class A Power Quality Instrument and Power Monitoring Device SICAM Q200 7KG97, Manual E50417-H1040-C621-A2, Edition 01.2020...
  • Page 10: Introduction

    2 data points (average, maximum) are published. The average value of the frequency has an independent, fixed aggregation interval of 10 s and the prefix is PQA4. SICAM, Class A Power Quality Instrument and Power Monitoring Device SICAM Q200 7KG97, Manual E50417-H1040-C621-A2, Edition 01.2020...
  • Page 11: Indications

    Load profile tariff 2 TOUTariffGGIO1$ST$Alm2 TOUTariffGGIO1 is the IEC 61850 GGIO LN name for TOU indications via the MQTT protocol; not via the IEC61850 protocol. SICAM, Class A Power Quality Instrument and Power Monitoring Device SICAM Q200 7KG97, Manual E50417-H1040-C621-A2, Edition 01.2020...
  • Page 12 Data-Points Mapping 1.2 Indications Index MQTT Name Q200 (Description) Name IEC 61850 (Name) Load profile tariff 3 TOUTariffGGIO1$ST$Alm3 Load profile tariff 4 TOUTariffGGIO1$ST$Alm4 SICAM, Class A Power Quality Instrument and Power Monitoring Device SICAM Q200 7KG97, Manual E50417-H1040-C621-A2, Edition 01.2020...
  • Page 13: Voltage Variations

    PQ_EVENTPHSAFF PQA_QVVR1$ST$AffPhs Enumeration – % (of V PQ_EVENTVVA PQA_QVVR1$MX$VVa Measured value rated PQ_EVENTVVATM PQA_QVVR1$MX$VVaTm Measured value Voltage Event PQA_QVVR1$ST$Dir$dirGeneral Enumeration – Direction General SICAM, Class A Power Quality Instrument and Power Monitoring Device SICAM Q200 7KG97, Manual E50417-H1040-C621-A2, Edition 01.2020...
  • Page 14: Transient Events

    Unit MQTT (Description) – PQA_QVTR1$ST$VarStr Indication – – PQA_QVTR1$ST$TrigPhs Enumeration – – PQA_QVTR1$ST$AffPhs Enumeration – – PQA_QVTR1$ST$PeakPhs Enumeration – – PQA_QVTR1$MX$MaxVTrs Measured value SICAM, Class A Power Quality Instrument and Power Monitoring Device SICAM Q200 7KG97, Manual E50417-H1040-C621-A2, Edition 01.2020...
  • Page 15: Measured Values

    – – MX$VAr$phsC $VAr$phsC – PQA2MMXU1$MX$TotVAr PQA2MMXN1$MX PQA2MMXU1$MX$VA$phsA $VolAmp PQA2MMXU1$ PQA2MMXU1$MX – – – MX$VA$phsB $VA$phsB PQA2MMXU1$ PQA2MMXU1$MX – – – MX$VA$phsC $VA$phsC SICAM, Class A Power Quality Instrument and Power Monitoring Device SICAM Q200 7KG97, Manual E50417-H1040-C621-A2, Edition 01.2020...
  • Page 16 – – X$ThdA$phsB $ThdA$phsB PQA2MHAI1$M PQA2MHAI1$MX THDR Ic – – – X$ThdA$phsC $ThdA$phsC PQA2MFLK1$MX PQA2MFLK1$MX$PhPst Pst (a-n) – – – – $PhPst $phsA SICAM, Class A Power Quality Instrument and Power Monitoring Device SICAM Q200 7KG97, Manual E50417-H1040-C621-A2, Edition 01.2020...
  • Page 17 3W2I 4W1I 4W3I PQA2MFLK1$MX Pst (b-n) – – – – – – $PhPst$phsB PQA2MFLK1$MX Pst (c-n) – – – – – – $PhPst$phsC SICAM, Class A Power Quality Instrument and Power Monitoring Device SICAM Q200 7KG97, Manual E50417-H1040-C621-A2, Edition 01.2020...
  • Page 18: Harmonics

    For all x in the names: x = 3, 5, 7, …, 25 indicating the (odd) harmonics number For all y in the names: y = 2, 4, 6, …, 24 indicating the (even) harmonics number SICAM, Class A Power Quality Instrument and Power Monitoring Device SICAM Q200 7KG97, Manual E50417-H1040-C621-A2, Edition 01.2020...
  • Page 19 PQA2MHAI1$MX$HW – – – H_Pa-x $HaWatt(x) $phsAHar(x) PQA2MHAI1$MX H_Pb-x – – – – – $HW$phsBHar(x) PQA2MHAI1$MX H_Pc-x – – – – – $HW$phsCHar(x) SICAM, Class A Power Quality Instrument and Power Monitoring Device SICAM Q200 7KG97, Manual E50417-H1040-C621-A2, Edition 01.2020...
  • Page 20: Measured Values (Min.)

    – MIN_PQA2MMXU1$MX$TotW MIN_PQA2MMXN MIN_PQA2MMXU1$MX$VAr$phsA 1$MX$VolAmpr MIN_PQA2MMX MIN_PQA2MMXU – – U1$MX$VAr – 1$MX$VAr$phsB $phsB MIN_PQA2MMX MIN_PQA2MMXU – – U1$MX$VAr – 1$MX$VAr$phsC $phsC – MIN_PQA2MMXU1$MX$TotVAr SICAM, Class A Power Quality Instrument and Power Monitoring Device SICAM Q200 7KG97, Manual E50417-H1040-C621-A2, Edition 01.2020...
  • Page 21 – – $MX$ThdPhV $ThdPPV$phsBC $phsB MIN_PQA2MHAI1 MIN_PQA2MHAI1$MX THDR Vc – – $MX$ThdPhV $ThdPPV$phsCA $phsC MIN_PQA2MHAI1 MIN_PQA2MHAI1$MX THDR Vab – – $MX$ThdPPVV $ThdPPV$phsAB $phsAB SICAM, Class A Power Quality Instrument and Power Monitoring Device SICAM Q200 7KG97, Manual E50417-H1040-C621-A2, Edition 01.2020...
  • Page 22 THDR Ia MIN_PQA2MHAI1$MX$ThdA$phsA $MX$ThdAmp MIN_PQA2MHAI MIN_PQA2MHAI1 THDR Ib – – 1$MX$ThdA – $MX$ThdA$phsB $phsB MIN_PQA2MHAI MIN_PQA2MHAI1 THDR Ic – – 1$MX$ThdA – $MX$ThdA$phsC $phsC SICAM, Class A Power Quality Instrument and Power Monitoring Device SICAM Q200 7KG97, Manual E50417-H1040-C621-A2, Edition 01.2020...
  • Page 23: Measured Values (Max.)

    – MAX_PQA2MMXU1$MX$TotW MAX_PQA2MMXN MAX_PQA2MMXU1$MX$VAr$phsA 1$MX$VolAmpr MAX_PQA2MM MAX_PQA2MMXU – – XU1$MX$VAr – 1$MX$VAr$phsB $phsB MAX_PQA2MM MAX_PQA2MMXU – – XU1$MX$VAr – 1$MX$VAr$phsC $phsC – MAX_PQA2MMXU1$MX$TotVAr SICAM, Class A Power Quality Instrument and Power Monitoring Device SICAM Q200 7KG97, Manual E50417-H1040-C621-A2, Edition 01.2020...
  • Page 24 – – $MX$ThdPhV $phsB MAX_PQA2MHAI1 THDR Vc – – – – – $MX$ThdPhV $phsC MAX_PQA2MHAI1 MAX_PQA2MHAI1$MX THDR Vab – – $MX$ThdPPVV $ThdPPV$phsAB $phsAB SICAM, Class A Power Quality Instrument and Power Monitoring Device SICAM Q200 7KG97, Manual E50417-H1040-C621-A2, Edition 01.2020...
  • Page 25 THDR Ia MAX_PQA2MHAI1$MX$ThdA$phsA 1$MX$ThdAmp MAX_PQA2MH MAX_PQA2MHAI1 THDR Ib – – AI1$MX$ThdA – $MX$ThdA$phsB $phsB MAX_PQA2MH MAX_PQA2MHAI1 THDR Ic – – AI1$MX$ThdA – $MX$ThdA$phsC $phsC SICAM, Class A Power Quality Instrument and Power Monitoring Device SICAM Q200 7KG97, Manual E50417-H1040-C621-A2, Edition 01.2020...
  • Page 26: Harmonics (Max.)

    For all x in the names: x = 3, 5, 7, …, 25 indicating the (odd) harmonics number For all y in the names: y = 2, 4, 6, …, 24 indicating the (even) harmonics number SICAM, Class A Power Quality Instrument and Power Monitoring Device SICAM Q200 7KG97, Manual E50417-H1040-C621-A2, Edition 01.2020...
  • Page 27 MAX_PQA2MHAI1$MX$HA$phsAHar(x) H_Ia-x $MX$HaAmp(x) MAX_PQA2MHA MAX_PQA2MHAI1 – – I1$MX$HA – $MX$HA H_Ib-x $phsBHar(x) $phsBHar(x) MAX_PQA2MHA MAX_PQA2MHAI1 – – I1$MX$HA – $MX$HA H_Ic-x $phsCHar(x) $phsCHar(x) SICAM, Class A Power Quality Instrument and Power Monitoring Device SICAM Q200 7KG97, Manual E50417-H1040-C621-A2, Edition 01.2020...
  • Page 28: Energy Values

    WQ_CAP_TARIFF_1 TOUTariffMMTR1$ST$DmdVArh $DmdVArh For the phase values, phsA, phsB, or phsC is added but it does not exist in a IEC 61850 LN. SICAM, Class A Power Quality Instrument and Power Monitoring Device SICAM Q200 7KG97, Manual E50417-H1040-C621-A2, Edition 01.2020...
  • Page 29 WS_TARIFF_3 TOUTariffMMTR3$ST$TotVAh $TotVAh TOUTariffMMTN4$ST WP_SUP_TARIFF_4 TOUTariffMMTR4$ST$SupWh $SupWh TOUTariffMMTN4$ST WP_DMD_TARIFF_4 TOUTariffMMTR4$ST$DmdWh $DmdWh TOUTariffMMTN4$ST WQ_IND_TARIFF_4 TOUTariffMMTR4$ST$SupVArh $SupVArh TOUTariffMMTN4$ST WQ_CAP_TARIFF_4 TOUTariffMMTR4$ST$DmdVArh $DmdVArh TOUTariffMMTN4$ST WS_TARIFF_4 TOUTariffMMTR4$ST$TotVAh $TotVAh SICAM, Class A Power Quality Instrument and Power Monitoring Device SICAM Q200 7KG97, Manual E50417-H1040-C621-A2, Edition 01.2020...
  • Page 30: Security Counters

    Name IEC61850 (Name) Remark (Description) – GSAL1$ST$AuthFail The counters start with 0 – GSAL1$ST$Login when the device is restarted or reset. – GSAL1$ST$Logout SICAM, Class A Power Quality Instrument and Power Monitoring Device SICAM Q200 7KG97, Manual E50417-H1040-C621-A2, Edition 01.2020...
  • Page 31: Literature

    Literature SICAM Q200, 7KG97xx Device Manual, V02.50 E50417-H1040-C606-A7 SICAM, Class A Power Quality Instrument and Power Monitoring Device SICAM Q200 7KG97, Manual E50417-H1040-C621-A2, Edition 01.2020...
  • Page 32 SICAM, Class A Power Quality Instrument and Power Monitoring Device SICAM Q200 7KG97, Manual E50417-H1040-C621-A2, Edition 01.2020...

Table of Contents