What's this?
• A user may prefer to initiate a call from particular phone port at a
particular timezone during a day. He may need to receive his trunk
or mobile call during morning hour on phone 1 and during
afternoon hours on phone 2.
• These examples highlight the need for the system to behave
differently depending on the time of the day. The SIMADO GBR42
offers a very flexible programming for different time zones. A day
can be divided in, four timezones. Such a schedule of a day is
called a Time Table. The gateway offers maximum of 8 time tables.
• Different Routing Type and Routing Group can be selected for
different time zones, which are defined by the time table, assigned
to the port.
• Time table can be assigned to each NT/TE/Mobile port.
How to program?
Step 1: To program start and stop time for timezone in a time table
using command 105.
Step 2: To assign a time table to a Mobile port using command 106.
Step 3: To assign a time table to a TE port using command 107.
Step 4: To assign a time table to a NT port using command 108.
Step 1
Use following command to program start and stop time for timezones
in a time table:
105-Time Table-Time Zone-Start Time-End Time-#*
Where,
Time Table is from 1 to 8.
Time Zone is from 1 to 4.
Start time is in form of HH:MM.
End time is in for of HH:MM.
HH is from 00 to 23.
MM is from 00 to 59.
SIMADO GBR42 V1 System Manual
Time Table
Matrix
159
Need help?
Do you have a question about the SIMADO GBR42 and is the answer not in the manual?