Use following command to enable/disable a NT port:
501-NT Port-Code-#*
Where,
NT Port is from 1 to 2.
Code Meaning
0
Disable
1
Enable
By default, NT port is enabled.
Step 2
Software (Logical) Port-Hardware (Physical) Port Association-
This command is used to assign a BRI hardware (physical) port to a
NT logical port.
Use following command to assign a BRI hardware (Physical) port to a
NT logical port:
502-NT Port-BRI Port-#*
Where,
NT Port is from 1 to 2.
BRI Port is from 1 to 2.
By default, NT Port 1 is assigned BRI Hardware Port 1 and NT
Port 2 is assigned BRI Hardware Port 2. Ensure that, jumper
setting is as per the Port Type, programmed.
Any ISDN Terminal Equipment like ISDN Phone, ISDN PBX or ISDN
Video Phone can be connected to this Port.
Step 3
Inter Digit Wait Timer-This timer signifies the time between two digits
dialed on the port. On expiry of this timer, the Gateway considers it to
be an end of string and proceeds with further call processing logic.
Use following command to program Inter digit wait timer for NT port:
504-NT Port-Inter Digit Wait Timer-#*
Where,
NT Port is from 1 to 2.
Inter digit wait timer is from 01 to 99 seconds.
By default, Inter Digit Wait Timer is 05 seconds.