Installation Guide
Precautions for the overload-caused burnt optical module
l
l
l
Other precautions
l
l
Cleaning Fiber Connectors
This section describes how to clean fiber connectors.
Procedure
Step 1 Clean the pins of a fiber connector by using lint-free cotton and alcohol.
Step 2 Clean the pins again by using dust-free cotton. If necessary, clean the pins by using an air gun.
----End
Cleaning MT Connectors (MTP/MTRJ) with Guide Pins
This topic describes how to clean the guide pins of MT connectors.
Procedure
Step 1 Clean the guide pins by using lint-free cotton and alcohol.
Step 2 Clean the pins again by using dry, lint-free cotton.
Step 3 Clean the pins by using an air gun.
----End
Installing an FC Fiber Connector
This section describes how to install an FC fiber connector.
Issue 02 (2011-09-10)
When using an OTDR to test the connectivity or the attenuation of optical signals,
disconnect the optical connector from the optical module. Otherwise, the optical module
is probably burnt.
When performing a self-loop test, use an optical attenuator. Do not loosen the optical
connector instead.
It is required that a long-distance optical module input optical power smaller than -7 dBm.
If the input optical power is larger than -7 dBm, you need to add an optical attenuator. For
example, if the transmiting optical power is X dBm and the optical attenuation is Y dB, the
receiving optical power is X-Y, which must be smaller than -7dBm (X-Y<-7 dBm).
The optical connector should be horizontally inserted in the receptacle to avoid damages
to the receptacle.
Mixed use of multi-mode and single-mode optical fibers is prohibited. Otherwise, faults
such as signal loss may occur.