Download Print this page

Huawei NetEngine80E Installation Manual page 101

Hide thumbs Also See for NetEngine80E:

Advertisement

HUAWEI NetEngine80E Router
Installation Guide
Table 5-2 Checklist for the installed power cables and grounding cables
No.
1
2
3
4
5
6
7
8
Cables Inside the Cabinet
Table 5-3
Issue 02 (2011-09-10)
Check Item and Description
Each power cable or grounding cable
must be a single cable with a copper wire
inside it. The cables must be connected
reliably according to the standards.
The power cables and grounding cables of
the devices are connected reliably. For
each grounding terminal, the spring
washer is placed on top of the flat washer.
The lug of a power cable or a grounding
cable are welded or pressed firmly.
The power cables and grounding cables
outside the cabinet are straight. They are
bundled separately from other types of
cables.
The extra ends of the power cables and
grounding cables are cut off instead of
being coiled.
The grounding cable for the cabinet door
is connected reliably and firmly.
Each power cable or grounding cable
must be labeled according to the
standards. The labels are stuck on a fixed
position on the cables and they face the
same direction (including the label on the
power distribution switch). It is
recommended that the labels be stuck at
20 mm (0.79 in.) away from the plugs.
The power cables and grounding cables
outside the cabinet are at least 30 mm
(1.18 in.) away from the signal cables.
lists the items that need to be checked for the installed cables inside the cabinet.
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
5 Powering on Devices
Method
-
-
-
Check this according to the following
figure.
-
-
-
-