HUAWEI NetEngine80E Router
Installation Guide
l
----End
Installing the Cord End Terminal
This section describes how to install a cord end terminal.
Procedure
Step 1 Hold a cord end terminal upright and place it on a terminal jack, as shown in
ensure bump contact and dense connection, place the plain side of the terminal outwards.
Figure 3-49 Placing a terminal on a terminal jack vertically
Step 2 Insert the terminal into the jack vertically, and fasten the terminal by turning the matching screw
in the clockwise direction, as shown in
Figure 3-50 Feeding the terminal into the jack
Issue 02 (2011-09-10)
CAUTION
If the two terminals are different in size, place the smaller one above the bigger one. A
maximum of two terminals can be installed on a post.
To remove an OT terminal, loosen the screw in the counterclockwise direction.
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
3 On-site Cable Assembly and Installation
Figure
3-50.
Figure
3-49. To
48