3.4.2 Installing Power Adapters
This section describes how to install OT terminals.
Installing the OT Terminal
This section describes how to install one or two OT terminals on a post.
Procedure
l
Issue 02 (2011-09-10)
Keep cables away from moveable components such as doors.
Sharp objects must not be touched in cable wiring to ensure that cables are not damaged.
To protect power cables, power cables of the active and standby power modules are laid
separately.
Install an OT terminal.
1.
Align the hole of the OT terminal (conductor upward) with a connecting hole, as shown
in
Figure
3-42.
Figure 3-42 Aligning the OT terminal with a connecting hole
NOTE
When you install an OT terminal, the crimping sleeve is installed as shown in
where A is correct and B is wrong.
Figure 3-43 Installing an OT terminal, showing the orientation of crimping sleeve
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
3 On-site Cable Assembly and Installation
Figure
3-43,
45