Goodrive100 inverters
Function
Name
code
stop function effective in any state for the fault reset.
The parameter
P07.05
selection1 of
running state
Detailed instruction of parameters
0:Only valid for the panel control
1:Both valid for panel and terminals control
2:Both valid for panel and communication control
3:Valid for all control modes
0x0000~0xFFFF
BIT0:running frequency (Hz on)
BIT1:set frequency(Hz flickering)
BIT2:bus voltage (Hz on)
BIT3:output voltage(V on)
BIT4:output current(A on)
BIT5:running rotation speed (rpm on)
BIT6:output power(% on)
BIT7:output torque(% on)
BIT8:PID reference(% flickering)
BIT9:PID feedback value(% on)
BIT10:input terminals state
IKR Aandrijven en Besturen
www.ikr-industries.nl
Keypad operation procedure
Default
Modify
value
○
0x03FF