Detailed instruction of parameters
Set the threshold point of the inverter:
0:Switch after 0 frequency
1:Switch after the starting frequency
0.00~100.00Hz
0: Detect at the setting speed
1: Detect at the feedback speed(only valid for vector control)
When P01.16=1, the actual output frequency of the inverter is
less than or equal to P01.15 and is detected during the time
set by P01.17, the inverter will stop; otherwise, the inverter
stops in the time set by P01.24.
Setting range: 0.0~100.0 s (only valid when P01.16=1)
When the running command channel is the terminal control,
the system will detect the state of the running terminal during
powering on.
0:The terminal running command is invalid when powering
on. Even the running command is detected to be valid during
powering on, the inverter won't run and the system keeps in
the protection state until the running command is canceled
and enabled again.