Goodrive100 inverters
Function
Name
code
PLC restart
P10.36
manner
selection
Multi-stage
P10.37
time unit
selection
Phase loss
P11.00
protection
Detailed instruction of parameters
BIT15 BIT14 15
After the users select the corresponding ACC/DEC time, the
combining 16 binary bit will change into decimal bit, and then
set the corresponding function codes.
Setting range: -0x0000~0xFFFF
0: Restart from the first stage; stop during running (cause by
the stop command, fault or power loss), run from the first
stage after restart.
1: Continue to run from the stop frequency; stop during
running(cause by stop command and fault), the inverter will
record the running time automatically, enter into the stage
after restart and keep the remaining running at the setting
frequency.
0: Seconds;the running time of all stages is counted by
second
1: Minutes;the running time of all stages is counted by
minute
P11 Group Protective parameters
0x00~0x11
LED ones:
IKR Aandrijven en Besturen
www.ikr-industries.nl
Keypad operation procedure
00
01
10
Default
value
11
0
0
11
Modify
◎
◎
○