Goodrive100 inverters
Function
Name
code
Function
P00.18
restore
parameter
P01.00
Start mode
Detailed instruction of parameters
bus voltage fluctuation.
0:No operation
1:Restore the default value
2:Clear fault records
Note: The function code will restore to 0 after finishing the
operation of the selected function code.
Restoring to the default value will cancel the user password,
please use this function with caution.
P01 Group Start-up and stop control
0:Start-up directly:start from the starting frequency P01.01
1:Start-up after DC braking: start the motor from the starting
frequency after DC braking (set the parameter P01.03 and
P01.04). It is suitable in the cases where reverse rotation
may occur to the low inertia load during starting.
2: Start-up after reverse tracing: start the rotating motor
smoothly after tracking the rotation speed and direction
automatically. It is suitable in the cases where reverse
rotation may occur to the big inertia load during starting.
Note: it is recommended to start the synchronous motor
directly.