Goodrive100 inverters
Function
Name
code
Restart after
P01.21
power off
The waiting
P01.22
time of restart
after power off
P01.23
Start delay
Detailed instruction of parameters
above the lower limit one.
Setting range: 0.0~3600.0s (valid when P01.19=2)
This function can enable the inverter start or not after the
power off and then power on.
0: Disabled
1: Enabled, if the starting need is met, the inverter will run
automatically after waiting for the time defined by P01.22.
The function determines the waiting time before the
automatic running of the inverter when powering off and then
powering on.
Setting range: 0.0~3600.0s (valid when P01.21=1)
The function determines the brake release after the running
command is given, and the inverter is in a stand-by state and
IKR Aandrijven en Besturen
www.ikr-industries.nl
Keypad operation procedure
Default
Modify
value
0
1.0s
0.0s