INVT Goodrive100 Series Instruction Manual page 87

Table of Contents

Advertisement

Goodrive100 inverters
Function
Name
code
QUICK/JOG
the shifting
sequence
P07.03
selection of
running
command
channel
P07.04
STOP/RST
Detailed instruction of parameters
Press QUICK/JOG to shift the direction of the frequency
commands. This function is only valid in the keypad
commands channels.
4:Clear UP/DOWN settings. Press QUICK/JOG to clear the
set value of UP/DOWN.
5: Coast to stop. Press QUICK/JOG to coast to stop.
6: Shift the running commands source. Press QUICK/JOG to
shift the running commands source.
7:Quick commission mode(committee according to the non-
factory parameter)
Note: Press QUICK/JOG to shift between forward rotation
and reverse rotation, the inverter does not record the state
after shifting during powering off. The inverter will run
according to parameter P00.13 during next powering on.
When P07.06=6, set the shifting sequence of running
command channels.
0:Keypad control→terminals control →communication control
1:Keypad control←→terminals control
2:Keypad control←→communication control
3:Terminals control←→communication control
Select the stop function by STOP/RST. STOP/RST is
IKR Aandrijven en Besturen
www.ikr-industries.nl
Keypad operation procedure
Default
Modify
value
0
0