Goodrive100 inverters
Function
Name
code
threshold
Energy-saving
P04.26
operation
selection
Voltage Setting
P04.27
Channel
selection
Detailed instruction of parameters
0:No operation
1:Automatic energy-saving operation
Motor on the light load conditions, automatically adjusts the
output voltage to save energy
Select the output setting channel at V/F curve separation.
0: Keypad setting voltage: the output voltage is determined
by P04.28.
1:AI1 setting voltage ;
2:AI2 setting voltage;
3:AI3 setting voltage;
4:HDI1 setting voltage;
5:Multi-stage speed setting voltage;
6:PID setting voltage;
7:MODBUS communication setting voltage;
8~10: Reversed
Note: 100% corresponds to the rated voltage of the motor.