Scope Port; Tx Generator Parameters - Viavi ATC-5000NG Operation Manual

Atc/dme test set
Table of Contents

Advertisement

5.8.2

SCOPE PORT

Command Syntax:
Description:
Numeric:
Default:
Example:
Query:
Return:
5.8.3

TX GENERATOR PARAMETERS

NOTE
The Generator commands are for use in the RTCA/DO-260 Test mode and Factory calibration
ONLY. To set power and frequency use commands listed under the specific test sections.
Rev. L0
February 2020
{:ATC |:ATC5000NG}{:SET |:SETTINGS}{:SCO |:SCOPE}{:CH1 | :CH2}SP<numeric>CR
This command sets the scope multiplexer for Scope 1 or Scope 2 to the signal represented by
the numeric value.
0 to 31 (decimal ASCII)
Value
Receiver
0
1090 Log Video Top
1030 Log Video Top
1
2
1090 Log Video Bottom
3
1030 Log Video Bottom
4
DPSK 1030 Top (Delay) Not Used
5
DPSK 1030 Bottom (Delay) Not Used
6
Transmitter 1 (Gen A) Pulse Modulation
7
Transmitter 2 (Gen B) Pulse Modulation
8
Transmitter 3 (Gen C) Pulse Modulation
9
Transmitter 4 (Gen D) Pulse Modulation
10
Transmitter 5 (Gen E) Pulse Modulation
Transmitter 6 (Gen F) Pulse Modulation
11
12
Transmitter 2 (Gen B) DPSK Modulation
13
Transmitter 4 (Gen D) DPSK Modulation
Transmitter 6 (Gen F) DPSK Modulation
14
15
I 1030 Top Receiver
16
I 1030 Bottom Receiver
17
Q 1030 Top Receiver
18
Q 1030 Bottom Receiver
19
I 1090 Top Receiver
20
I 1090 Bottom Receiver
21
Q 1090 Top Receiver
22
Q 1090 Bottom Receiver
23
Suppression In
Sync
24
25
Sync (Transmitter FPGA Test Point)
26
Log Video 1030 Digital AGC Video
Log Video 1090 Digital AGC Video
27
28
DPSK Demodulation
29
+3.3 V Monitor
30
+1.8 V Monitor
31
+1.2 V Monitor
Last state before power down.
:ATC:SET:SCO:CH1 24\r
:ATC:SET:SCO:CH1?\r
24
ATC-5000NG ATC/DME Test Set Operation Manual
Subject to Export Control. See Cover Page for details.
Operation, Remote Operation
Settings Commands
1-2-5
Page 99

Advertisement

Table of Contents
loading

This manual is also suitable for: