Mode S Interrogation:
P1 to P2 Default:
Accuracy:
P2 Variation:
Resolution:
Accuracy:
P6 to SPR Default:
Accuracy:
P6 Variation:
Resolution:
Accuracy:
P2 to SPR Default:
Accuracy:
SPR Variation
Resolution:
Accuracy:
P5 prior SPR Default:
Accuracy:
P5 Variation
Resolution:
Accuracy:
Interference Pulse:
Signal 1 (relative to P1):
Resolution:
Accuracy:
Signal 2 (relative to Signal 1):
Resolution:
Accuracy:
Double/Interlace Interrogation (P1 to P1):
Resolution:
Accuracy:
DME:
P1 to P2 Default:
Accuracy:
P1 to P2 Variable:
DME X:
Resolution:
Accuracy:
DME Y:
Resolution:
Accuracy:
Rev. L0
February 2020
3
:
3
:
ATC-5000NG ATC/DME Test Set Operation Manual
Subject to Export Control. See Cover Page for details.
Specifications, ATC-5000NG Performance Specifications
2.0 s
10 ns
1.95 s
25 ns
10 ns
1.25 s
15 ns
1.95 s
25 ns
15 ns
2.75 s
15 ns
1.0 s
25 ns
15 ns
400 ns
15 ns
1.95 s
25 ns
15 ns
-17.5 to 400 s
25 ns
20 ns
0 to 400 s
25 ns
10 ns
0 to 400 s
25 ns
10 ns
12 or 30 s
50 ns
-2.5 to +7.9 s
25 ns
50 ns
7.9 s
25 ns
50 ns
2
Transmitter, Pulse Position
1-3-1