Spr; Trigger Parameters - Viavi ATC-5000NG Operation Manual

Atc/dme test set
Table of Contents

Advertisement

5.3.5.6
PULSE WIDTH REQUEST
Command Syntax:
Description:
Example:
Return:
5.3.6

SPR

Command Syntax:
Description:
Numeric:
Example:
Default:
Query:
Return:
5.3.7

TRIGGER PARAMETERS

5.3.7.1
ANTENNA
Command Syntax:
Description:
Example:
Default:
Query:
Return:
5.3.7.2
DBM LEVEL
Command Syntax:
Description:
Numeric:
Example:
Query:
Return:
1-2-5
Page 10
{:ATC |:ATC5000NG}{:MEA |:MEASURE}{:PUL |:PULSE}{:WID? |:WIDTH?} CR
This command returns the pulse width of the selected pulse.
:ATC:MEA:PUL:WID?\r
Value is in ASCII data format specified in ns. In case of the Float data format, the Value is
returned without fractional part.
If no measurement Value is available, the Unit replies with not ready "#".
{:ATC |:ATC5000NG}{:MEA |:MEASURE}{:SET |:SETTINGS}{:SPR}SP<numeric>CR
This command sets the measurement routine to sample the selected SPR.
0 to 112 (decimal ASCII)
0 is the Sync Phase Reversal of the P6 pulse. 1 is the first bit of the interrogation.
:ATC:MEA:SET:SPR 27\r
0
:ATC:MEA:SET:SPR?\r
27
Measured pulse must be set to "P6 SPR" or the query will return "?".
{:ATC |:ATC5000NG}{:MEA |:MEASURE}{:SET |:SETTINGS}{:TRIGGER |:TRIG}{:ANT
|:ANTENNA}SP{TOP |BOTTOM}CR
This command sets the measurement routine to sample the Top or Bottom antenna.
:ATC:MEA:SET:TRIG:ANT TOP\r
Top
:ATC:MEA:SET:TRIG:ANT?\r
TOP
{:ATC |:ATC5000NG}{:MEA |:MEASURE}{:SET |:SETTINGS}{:TRIGGER
|:TRIG}{:LDBM}SP<numeric>CR
This command sets the trigger level in dBm if trigger source is set to log video.
15 to 60 dBm (decimal ASCII)
:ATC:MEA:SET:TRIG:LDBM 20\r
:ATC:MEA:SET:TRIG:LDBM?\r
20
ATC-5000NG ATC/DME Test Set Operation Manual
Subject to Export Control. See Cover Page for details.
Operation, Remote Operation
Measurement Commands
Rev. L0
February 2020

Advertisement

Table of Contents
loading

This manual is also suitable for:

138156

Table of Contents