5.7.2.21.1.S
VERTICAL VELOCITY SOURCE / GEO FLAG
Command Syntax:
Description:
Numeric:
Default:
Example:
5.7.2.21.2
VELOCITY MESSAGE SCHEDULE
Velocity squitter is transmitted by the ATC-5000NG at a rate of 0.5 seconds.
Dynamic intruders (targets) allow definition of multiple time intervals where the Velocity squitter can be
enabled or disabled.
Static intruders (targets) allow the user to enable or disable the Velocity squitter for the entire scenario.
5.7.2.21.2.A
DYNAMIC VELOCITY SCHEDULE
5.7.2.21.2.A.1
Command Syntax:
Description:
Default:
Example:
5.7.2.21.2.A.2
Command Syntax:
Description:
Numeric:
Example:
5.7.2.21.2.A.3
Command Syntax:
Description:
Numeric:
Example:
1-2-5
Page 78
{:ATC |:ATC5000NG}{:SCE |:SCENARIO}{:STAT: |:STATIC: |:DYN: |:DYNAMIC:}< intruder no
>{:VVSOURCE}SP<numeric>CR
This command sets the Vertical Velocity source or GEO flag of the specified intruder.
0 to 1 (decimal ASCII)
Value
0
1
0
:ATC:SCE:DYN:1:VVSOURCE 1\r
INTERVAL ENABLE
{:ATC |:ATC5000NG}{:SCE |:SCENARIO}{:DYN: |:DYNAMIC:}<intruder no>{:SVEL}{:INT:
|:INTERVAL:}<interval number>{:ENA |:ENABLE}SP{ON | OFF}CR
This command enables or disables the velocity squitter message of the specified intruder.
On
:ATC:SCE:DYN:2:SVEL:INT:2:ENA ON\r
INTERVAL QUANTITY
{:ATC |:ATC5000NG}{:SCE |:SCENARIO}{:DYN: |:DYNAMIC:}<intruder no>{:SVEL}{:NINT
|:NINTERVALS}SP<numeric>CR
This command sets the number of velocity squitter message intervals for the selected intruder.
The spaces not defined between intervals are considered off; therefore,
define the intervals where the message
0 to 255 (decimal ASCII)
:ATC:SCE:DYN:1:SVEL:NINT 3\r
INTERVAL START TIME
{:ATC |:ATC5000NG}{:SCE |:SCENARIO}{:DYN: |:DYNAMIC:}<intruder no>{:SVEL}{:INT:
|:INTERVAL:}<interval number>{:BEGIN}SP<numeric>CR
This command sets the start time for the selected velocity squitter message interval for the
selected intruder. The spaces not defined between intervals are considered off; therefore,
can define the intervals where the message
the user
0 to 6550 seconds (decimal ASCII). Resolution is 0.1 seconds.
:ATC:SCE:DYN:2:SVEL:INT:2:BEGIN 86\r
ATC-5000NG ATC/DME Test Set Operation Manual
Subject to Export Control. See Cover Page for details.
Meaning
Vertical Rate information from Geometric Source
Vertical Rate information from Barometric Source
transmitted
is
Operation, Remote Operation
Scenario Commands
only
can
the user
.
only
transmitted
is
.
Rev. L0