Pulse - Viavi ATC-5000NG Operation Manual

Atc/dme test set
Table of Contents

Advertisement

5.3.4

PULSE

Command Syntax:
Description:
Example:
Default:
Query:
Return:
1-2-5
Page 8
{:ATC |:ATC5000NG}{:MEA |:MEASURE}{:SET |:SETTINGS}{:PUL |:PULSE}SP<value>CR
This command sets the measurement routine to sample the selected pulse. Pulse selected to
sample interrogation is ignored when the scenario type selected is XPDR.
Value
Pulse
0|F1
F1 ATCRBS Reply
1|C1
C1 ATCRBS Reply
2|A1
A1 ATCRBS Reply
3|C2
C2 ATCRBS Reply
A2 ATCRBS Reply
4|A2
5|C4
C4 ATCRBS Reply
6|A4
A4 ATCRBS Reply
B1 ATCRBS Reply
7|B1
8|D1
D1 ATCRBS Reply
9|B2
B2 ATCRBS Reply
10|D2
D2 ATCRBS Reply
11|B4
B4 ATCRBS Reply
12|D4
D4 ATCRBS Reply
13|F2
F2 ATCRBS Reply
14|P1MSR
P1 Mode S Reply
15|P2MSR
P2 Mode S Reply
16|P3MSR
P3 Mode S Reply
P4 Mode S Reply
17|P4MSR
18|S1MCI
S1 ATCRBS Interrogation
19|P1MCI
P1 ATCRBS Interrogation
P2 ATCRBS Interrogation
20|P2MCI
21|P3MCI
P3 ATCRBS Interrogation
22|P4MCI
P4 ATCRBS Interrogation
23|P1MSI
P1 Mode S Interrogation
24|P2MSI
P2 Mode S Interrogation
25|P6MSIR
P6 Start Interrogation
26|P6MSIF
P6 End Interrogation
27|P6MSI
P6 Mode S Interrogation
28|P6SPR
P6 SPR
29|MCSPI
SPI ATCRBS Reply
DF Frame Data
30|DFDATA
31|DMEXP1
DME X P1
32|DMEXP2
DME X P2
DME Y P1
33|DMEYP1
34|DMEYP2
DME Y P2
35|MCXBIT
X ATCRBS Reply
:ATC:MEA:SET:PUL 18\r
Scenario Type
XPDR
MULTI (Multi-Receiver)
0|F1
19|P1MCI
:ATC:MEA:SET:PUL?\r
18
ATC-5000NG ATC/DME Test Set Operation Manual
Subject to Export Control. See Cover Page for details.
Operation, Remote Operation
Measurement Commands
Rev. L0
February 2020

Advertisement

Table of Contents
loading

This manual is also suitable for:

138156

Table of Contents