Adjusting and replacing sealing strips
 Park the machine on an even surface.
 Turn the programme selector switch to
"OFF" and remove the KIK-key.
Side brush and roller brush are raised.
 Activate parking brake.
 Front sealing strip
 Loosen the plastic screws by approx. 2
turns, do not completely unscrew them.
 Set the distance between the sealing
strip and the floor so that the bottom
edge trails behind at a distance of be-
tween 10-15 mm.
 Tighten the screws.
Caution: Do not strip plastic screws!
If worn, replace.
 For replacement unscrew the screws,
attach new sealing strip and retaining
plate, adjust and tighten screws.
 Rear sealing strip
 Loosen the plastic screws by approx. 2
turns, do not completely unscrew them.
 Set the distance between the sealing
strip and the floor so that the bottom
edge trails behind at a distance of be-
tween 5 and 10 mm.
 Tighten the screws.
Caution: Do not strip plastic screws!
If worn, replace.
 For replacement unscrew the screws,
attach new sealing strip and retaining
plate, adjust and tighten screws.
 Side sealing strips
 Loosen the plastic screws by approx. 2
turns, do not completely unscrew them.
 To set the floor clearance, insert a
sheet with a thickness of between 1 and
3 mm under the sealing strip.
 Adjust sealing strip.
 Tighten the screws.
Caution: Do not strip plastic screws!
If worn, replace.
 For replacement unscrew the screws,
attach new sealing strip and retaining
plate, adjust and tighten screws.
Check/replace dust filter
WARNING
Health hazard!
 Wear a dust mask when working
around the dust filter. Observe safety
regulations on the handling of fine parti-
cles.
Note: Wait at least 1 minute before remov-
ing the dust filter so that the dust can settle.
Figure: KM 125/... with 3 flat fold filters; KM
105/... has 2 flat fold filters
1 Lid with cleaning device
2 Screw
3 Support
4 Dust filter (flat-fold filter)
 Unscrew the screw.
 Fold the lid up and secure it by means
of the support.
 Take out the dust filter.
 Check dust filter.
 Insert cleaned or new dust filter.
 Close the lid.
 Screw in the screws and tighten them.
Check/clean protective grid oil cooler
(only with KM 125/...)
1 Protective grid oil cooler
2 Oil cooler
 Check the protective grid of the oil cool-
er for contamination daily, clean if nec-
essary.
 Check the inside of the oil cooler for
soiling every once in a while, remove
the protective grid and clean the oil
cooler if necessary.
18
-
EN
Check suction blower
 Have the suction blower checked for
leaks.
Only by customer service.
Checking drive belt
 Check tension of V-Belt.
Only by customer service.
Replacing fuses of drive control/
electronic system
The appliance (without upgrade kits) is
equipped with two fuses with 5 A fuse pro-
tection each. They are located under the
appliance cover.
If fuses are defective, contact the author-
ised aftersales service.
Additional fuses for the oil cooler
FM 31
Oil cooler engine
FK 31
Oil cooler contactor
The diesel version has an additional fuse
FU20 with 30 A fuse protection. It can be
replaced by the customer in case of defect,
in order to do so, swivel the left bonnet to
the side.
7.5 A
5 A
45