Preventive Maintenance and Fault-finding
6.5
Changing the Equipment Fuse
This product should be operated only from the type of power source indicated on the marking label. If
you are not sure of the type of power supply to your home or business, consult your appliance dealer or
local power company. For products intended to operate from battery power, or other sources, refer to the
The power supply used in this equipment is a wide-ranging, ac power
supply unit designed for use in ambient air temperature conditions of 0°C
to +50°C for 100-120 Vac and 220-240 Vac, 50-60 Hz (see Annex B,
Technical Specification for details). There are no links or switches to be
altered for operation from different ac supplies.
The Alteia is designed for user accessible fuse replacement.
In addition to the fuse in the supply cable plug (if appropriate) a fuse is
held in the fuse carrier of the ac power inlet at the rear of the Alteia.
Table 6.1: Fuse Information
Item
Fuse
Fuse type
Fuse rating
To replace the ac power fuse perform the following:
BEFORE REPLACING THE REAR PANEL FUSE, DISCONNECT THE EQUIPMENT FROM THE
SUPPLY. FAILURE TO DO THIS MAY EXPOSE HAZARDOUS VOLTAGES. UNPLUG THE
1. Ensure that power is turned off and the power cable is disconnected
from the ac power inlet.
2. Ease out the fuse carrier by placing a small, flat-bladed screwdriver in
the notches at the sides of the carrier.
When replacing the power input fuse, always ensure that a fuse of the correct type and rating is fitted.
Failure to do so results in inadequate protection. If the replacement fuse also blows, do not continue.
Disconnect the equipment and contact Customer Services (see Preliminary Pages) for advice.
3. Replace the fuse in the carrier.
4. Insert the fuse carrier back in the ac power inlet.
Figure 6.1: Fuse Carrier
Page 6-8
Specification
Single pole, fitted in live conductor in power input filter at rear of unit.
5 mm x 20 mm anti-surge (T) HBC, IEC127 (sheet v)
1.6 A, 250 Vac
EQUIPMENT FROM THE LOCAL SUPPLY SOCKET.
AC Power Inlet
Fuse Carrier
Instruction Manual: Alteia and Alteia plus Professional Receivers and Decoders
CAUTION...
operating instructions.
WARNING...
CAUTION...
To access the fuse, ease out the notch
with a small flat-blade screwdriver.
ST.TM.E9200.8

Advertisement

Table of Contents
loading

This manual is also suitable for:

Alteia plus

Table of Contents