B.4.4

Data Outputs

RS-232 Asynchronous (Low-speed) Data

Table B.32: RS-232 Asynchronous (Low-speed) Data Connector
Item
Safety status
Data-rates (bit/s)
Standards
Line length

RS-422 Synchronous (High-speed) Data

Table B.33: RS-422 Synchronous (High-speed) Data Connector
Item
Safety status
Data-rates (bit/s)
NOTE...
High-speed RS-422 Synchronous data is available on suffix A Alteias (e.g. M2/PSR/942A) and Alteia
plus.
B.4.5

Auxiliary Relay Interface

Automatic Gain Control (AGC) Output

Table B.34: Automatic Gain Control (AGC) Output
Item
Safety status
Connector type
Output impedance
Output voltage range
NOTE...
The AGC output is available on Receivers only.
Page B-18
Specification
SELV
1200; 2400; 4800; 9600; 19 200
EIA RS-232C / ITU-T BT. V.24/V.28
< 15 metres
Specification
SELV
In integer multiples of 56 kbit/s and 64 kbit/s up to 2.048 Mbit/s
(Subject to the number and type of services in the multiplex)
Specification
SELV
Female
10 kW ±1%
0 - 10 Volts into 10 kW ±1% termination when RF varies as in Table B.7