Terrestrial And Digital Eng Receiver Alarm Menu Pages - TANDBERG Alteia Instruction Manual

Professional receivers and decoders
Table of Contents

Advertisement

C.8.3
Terrestrial and Digital ENG Receiver Alarm Menu
Pages
This section applies to the M2/PTR[E]/942[B][C][D] and M2/PTR/948[A]
models.
Table C.13: Terrestrial Alarm Menu (#5) Pages
Page
Display
1
#5 ALARM
PAGE 2 - - - - 9 - - - - 14
T
STAT
2
#5 ALARM
selectable
INPUT
FAIL NO
3
#5 ALARM
selectable
POS V BER
OK
4
#5 ALARM
selectable
VIDEO
OK
5
#5 ALARM
selectable
VBI
OK
6
#5 ALARM
selectable
AUDIO 1
OK
7
#5 ALARM
selectable
AUDIO 2
OK
8
#5 ALARM
selectable
ASYNC
OK
9
#5 ALARM
selectable
SYNC
OK
10
#5 ALARM
selectable
CA
FAIL
11
#5 ALARM
selectable
PMT
FAIL
12
#5 ALARM
selectable
POST RS
FAIL
13
#5 ALARM
selectable
TPS
FAIL
14
#5 ALARM
TEMPERATURE
OK
15
#5 ALARM
TIME SYNC
OK
16
#5 ALARM
Selectable
USER ALARM MASK
STORE
Instruction Manual: Alteia and Alteia plus Professional Receivers and Decoders
ST.TM.E9200.8
Description
[FAIL] 1/164
This page provides a summary of the alarm status. Each number
corresponds to an Alarm Menu page. An asterisk shows which page is
contributing to the summary Alarm.
32/164
RELAY MASK
1
YES
33/164
RELAY MASK
1
YES
34/164
RELAY MASK
1
YES
35/164
RELAY MASK
2
YES
36/164
RELAY MASK
NONE
YES
37/164
RELAY MASK
NONE
YES
38/164
RELAY MASK
NONE
NO
39/164
RELAY MASK
NONE
NO
310/164
RELAY MASK
NONE
YES
311/164
Program Map Table (PMT) not
RELAY MASK
available.
NONE
YES
312/164
Post Reed-Solomon errors
RELAY MASK
(POST RS) indicates RS Decoder
NONE
YES
failure.
313/164
Transmitter Parameter Signalling
RELAY MASK
(TPS) failed.
NONE
YES
314/164
This is a non-editable page. The temperature is shown in both Celsius
and Fahrenheit and shows if the internal temperature exceeds 60°C.
27C
75F
315/164
Provides an alarm if the timing recovery is not in lock.
RELAY MASK
NONE
NO
316/16
This page allows the current mask configuration to be stored (default is
all alarms masked). Restore allows the user to recall the previously
NONE
NO
stored mask (which could be the default).
These pages display the status of
the module or function
i
ndicated by the title on line 2.
The RELAY parameter allows an
Alarm to be associated with a
particular relay contact at the rear
of the unit. If a relay is selected
and a failure occurs, that relay
activates. See additional
comments in section C.8.2
The MASK parameter allows an
Alarm to be masked so that it
does not contribute to the
Summary Alarm.
Menus
Options
PAGE number
(2 to 18)
ALARM
STATUS —
OK, FAIL
RELAY —
NONE (default)
1, 2, 3, 4, 5 or 6
MASK —
YES (default),
NO
OK, FAIL
OK, FAIL
STORE,
RESTORE
Page C-21