Fan Removal
1.
To remove the fan finger guard from the drive, push the hook on the back side of the fan finger guard and pull
up.
A - Fan finger guard
2.
Pull the cooling fans straight up from the drive. Disconnect the relay connectors and remove the fans from the
drive.
A - Cooling fans
Fan Installation
Reverse the removal procedure for fan installation.
1.
Connect the relay connectors between the drive and cooling fans.
YASKAWA TOEPYAIGA8001B GA800 Drive Maintenance & Troubleshooting
Figure 1.7 Remove the Fan Finger Guard
Figure 1.8 Remove the Cooling Fans
Figure 1.9 Connect the Relay Connectors