3.8 E: Motor Parameters
No.
Name
(Hex.)
E9-07
Motor Rated Power
(11EA)
E9-08
Motor Pole Count
(11EB)
E9-09
Motor Rated Slip
(11EC)
E9-10
Motor Line-to-Line
Resistance
(11ED)
182
V/f
CL-V/f
OLV
CLV
AOLV
Sets the motor rated output in the units from o1-58 [Motor Power Unit Selection].
V/f
CL-V/f
OLV
CLV
AOLV
Sets the number of motor poles.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the motor rated slip.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the line-to-line resistance for the motor stator windings.
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
YASKAWA TOEPYAIGA8001B GA800 Drive Maintenance & Troubleshooting
Default
(Range)
Determined by E9-02 and
o2-04
(0.00 - 650.00 kW)
4
(2 to 120)
0.000 Hz
(0.000 - 20.000 Hz)
Determined by o2-04
(0.000 - 65.000 Ω)