1.4 Replace Cooling Fans and Circulation Fans
A - Cooling fans
B - Cable hooks
C - Relay connectors
4.
Put the fan unit into the specified location.
5.
Slide the fan unit to the right and use the screws to safety it to the drive.
Tighten the screws to a correct tightening torque:
• Screws in Position A: 0.98 N∙m to 1.33 N∙m (8.67 lbf∙in to 11.77 lbf∙in)
• Screws in Position B: 1.96 N∙m to 2.53 N∙m (17.35 lbf∙in to 22.39 lbf∙in)
50
Figure 1.55 Put the Cables and Connectors in the Drive Recess
Figure 1.56 Install the Fan Unit
D - Relay cables
E - Circulation fan