3.10 H: Terminal Functions
No.
Name
(Hex.)
H2-63
Term M3-M4 Secondary
Function
(1B49)
Expert
H2-64
Terminal M3-M4 Logical
Operation
(1B4A)
Expert
H2-65
Terminal M3-M4 Delay
Time
(1B4B)
Expert
H2-66
Term M5-M6 Secondary
Function
(1B4C)
Expert
H2-67
Terminal M5-M6 Logical
Operation
(1B4D)
Expert
H2-68
Terminal M5-M6 Delay
Time
(1B4E)
Expert
H2-xx: MFDO Setting Values
Setting Value
Function
0
During Run
1
Zero Speed
2
Speed Agree 1
208
V/f
CL-V/f
OLV
CLV
AOLV
Sets the second function for terminal M3-M4. Outputs the logical calculation results of the terminals
assigned to functions by H2-02 [Term M3-M4 Function Selection].
V/f
CL-V/f
OLV
CLV
AOLV
Sets the logical operation for the functions set in H2-02 [Term M3-M4 Function Selection] and H2-
63 [Term M3-M4 Secondary Function].
V/f
CL-V/f
OLV
CLV
AOLV
Sets the minimum on time used to output the logical calculation results from terminal M3-M4.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the second function for terminal M5-M6. Outputs the logical calculation results of the terminals
assigned to functions by H2-03 [Terminal M5-M6 Function Select].
V/f
CL-V/f
OLV
CLV
AOLV
Sets the logical operation for the functions set in H2-03 [Term M5-M6 Function Selection] and H2-
66 [Term M5-M6 Secondary Function].
V/f
CL-V/f
OLV
CLV
AOLV
Sets the minimum on time used to output the logical calculation results from terminal M5-M6.
V/f
CL-V/f
OLV
CLV
AOLV
The terminal activates when you input a Run command and when the drive is outputting voltage.
ON : Drive is running
OFF : Drive is stopping
V/f
CL-V/f
OLV
CLV
AOLV
The terminal activates when the output frequency < E1-09 [Minimum Output Frequency] or b2-01 [DC Injection/Zero
SpeedThreshold].
Note:
Parameter A1-02 [Control Method Selection] selects which parameter is the reference.
A1-02 Setting
0
V/f
1
CL-V/f
2
OLV
3
CLV
4
AOLV
5
OLV/PM
6
AOLV/PM
7
CLV/PM
8
EZOLV
ON : Output frequency < value of E1-09 or b2-01.
OFF : Output frequency ≥ value of E1-09 or b2-01.
V/f
CL-V/f
OLV
CLV
AOLV
The terminal turns on when the output frequency is in the range of the frequency reference ± L4-02 [Speed Agree Detection Width].
Note:
• The detection function operates in the two motor rotation directions.
• The drive outputs the motor speed status when A1-02 = 3, 7 [CLV, CLV/PM]. It also outputs the motor speed status when A1-
02 = 4 and n4-72 = 1.
ON : The output frequency is in the range of "frequency reference ± L4-02".
OFF : The output frequency does not align with the frequency reference although the drive is running.
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Control method selection
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
YASKAWA TOEPYAIGA8001B GA800 Drive Maintenance & Troubleshooting
Default
(Range)
F
(0 - FF)
0
(0 - 8)
0.1 s
(0.0 - 25.0 s)
F
(0 - FF)
0
(0 - 8)
0.1 s
(0.0 - 25.0 s)
Parameter Used as the Reference
E1-09
E1-09
b2-01
E1-09
E1-09
E1-09
E1-09
b2-01
E1-09